8.
Heat preservation:
1.When water is boiling and enters the heat preservation state, the device
will start timing of heat preservation;
2.During heat preservation, the error between display temperature and
actual temperature is required to be controlled within ±5°C;
3.When (set temperature - 10) ≤ water temperature ≤ (set temperature - 2),
the device will launch adjustable power heating (if the highest temperature
is 1°C higher than set temperature during the previous heat preservation,
the adjustable power ratio is 3/35; in other cases, the ratio is 4/25); When
water temperature > (set temperature - 10), the adjustable power ratio is
8/25.
9.
Mode selection:
Button “ ”: Heat water to set temperature and automatically enter the heat
preservation state;
Button “ ”: Heat water to 100°C (boiling) and automatically enter the
standby state;
10.
Temperature selection/ON-OFF:
Button “ ”: Cyclical selection of set temperature: 40-50-60-70-80-90°C;
Button “ ”: Enter the standby state by pressing it from the shutdown state,
while enter the shutdown state by pressing it from the standby/operation
state.
7
Operating Instructions
Note:
When the power is on, the default temperature target is 100°C or the
temperature target during the operation in the previous time.
In the non-temperature setting state, press “ ” to display the current
temperature target and enter the temperature setting state.
11.
Power-on display:
When the power is on, the nixie tube is fully bright for around 0.5 second
and the device enters the standby state.
12.
Temperature display:
1.The device displays real-time water temperature in standby/heating state;
2.When temperature selection/or operation begins, light always-on displays
set temperature for about one second, but the device will display current
temperature without any operation while the light flickers again for about 1.5
seconds;