Middle Atlantic Products Cool Series Instruction Sheet Download Page 7

1)  Lay  Ductwork out  between  Intake Assembly and  Fan  Unit.

NOTE:  Fully extend  Flexible  Duct  (D)  minimizing  the  number of bends.  Minimizing  the  number of 

bends  maximizes  air flow.

FLEXIBLE DUCT INSTALLATION

2)  Pull  back outer insulation  on  both  ends.

3) Attach  Flexible  Duct to  Louvered  Intake with  provided  Clamp  (E). 

(FIGURE A)

4)  Cut Flexible  Duct to  appropriate  length.

5) Attach  Flexible  Duct to  Fan  Unit with  provided  Clamp  (E). 

(FIGURE  B)

NOTE:  Duct Tape  can  be  used with  the  Clamps for extra  hold.

6)  Plug  in  the  power cord  and  your DUCT-COOL  is  ready for use.  (FIGURE  C)

FIGURE  B

Page 7

Summary of Contents for Cool Series

Page 1: ...d these instructions thoroughly before installing assembling this product PRODUCT FEATURES Removes air from enclosed areas with minimal noise Inline mixed flow duct fan is quieter and more efficient than centrifugal fans Operates only when needed minimizing noise and dust M iddle Atlantic Products I 00248 Rev C ...

Page 2: ...Pour usage de ventilation generale seulement ne pas utiliser pour echappement nocifs ou explosives matieres et les vapeurs A Ac CAUTION Automatically operated device to reduce the risk of injury disconnect from power supply before performing any maintenance operations ATTENTION Dispositif fonctionnement automatique pour reduire le risque de blessures debrancher a partir de source de courant avant ...

Page 3: ...BLE DUCT CLAMPS QTY QTY PART D PART E 1 3 10 32 x 1 2 PHILLIPS HEAD SCREW QTY PART 5 F CABLE TIE MOUNT QTY 12 10 32 LOCKNUT TEMPERATURE PROBE CONNECTOR TEMPERATURE PROBE WIRE 30 FEET QTY PART 5 One Extra One Extra H QTY PART 1 K QTY PART 1 M 10 x 5 8 WOOD SCREW QTY 12 WIRE TIE INTAKE TEMPLATE QTY 24 QTY 1 Page 3 PART G PART J PART L PART N ...

Page 4: ...te to mark installation location NOTE Hole size is 7 1 8 3 Cut hole using desired method hand saw power saw etc FIGURE A INTAKE ASSEMBLY INSTALLATION 4 Insert Intake Assembly A into the hole FIGURE B 5 Tighten the four screws on the Intake using a Phillips Head screwdriver The clips will automatically swing into the proper position securing the Intake Assembly FIGURE C ...

Page 5: ...n mount on Mounting Plate in two directions adjustable slots allow for two inch shift either way off center position FIGURE B 2 Determine mounting location in attic Mounts to joists or structurally sound flat surface NOTE Make sure airflow faces away from Louvered Intake airflow shown on label affixed to fan unit and on electrical box 3 Mount Fan Unit as desired using customer supplied hardware FI...

Page 6: ... to properly gauge temperature See FIGURE A for an example of a Temperature Probe Assembly installation 2 Drill a 1 8 hole where the Temperature Probe M will be located 3 Run Temperature Probe Wire along joist and secure with provided Wire Ties L Wood Screws J and Cable Tie Mounts G Place Probe lead through previously drilled 1 8 hole 4 If desired cut the stripped ends of the Temperature Probe Wir...

Page 7: ...UCT INSTALLATION 2 Pull back outer insulation on both ends 3 Attach Flexible Duct to Louvered Intake with provided Clamp E FIGURE A 4 Cut Flexible Duct to appropriate length 5 Attach Flexible Duct to Fan Unit with provided Clamp E FIGURE B NOTE Duct Tape can be used with the Clamps for extra hold 6 Plug in the power cord and your DUCT COOL is ready for use FIGURE C FIGURE B Page 7 ...

Page 8: ...F ALL OTHER WARRANTIES OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW IN NO EVENT SHALL THE COMPANY BE LIABLE FOR ANY SPECIAL INCIDENTAL INDIRECT OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSIN...

Reviews: