Table 5 Additional Commands for Prior Design Compatibility
Command Name
Code
Description
Calibrate Interactive
CI
Initiates an interactive, two-point edge calibration.
Calibrate New
CN
Initiates an interactive, two-point
edge
calibration.
Filter Number
FN
nn
Sets the number of X/Y values that the controller
uses to generate an accurate coordinate after the
touchscreen receives an initial touch.
Format Binary [Stream]
FB[S]
Outputs the X/Y touch coordinate data as a five byte
packet in a binary (or binary stream) format.
Format Hexadecimal
FH
Outputs the X/Y touch coordinate data as a nine byte
packet in a hexadecimal format.
Format Zone
FZ
Outputs the X/Y touch coordinate data as a five byte
packet and indicates whether the touch occurred
inside or outside the calibration area.
Frequency Adjust
<Ctrl> C
F
nn
Lets you change the operating frequency of the
sensor drive signal (DRVOUT) that is fed from the
controller to the sensor and drives the sensor output.
Get Parameter Block
GP
Returns all power-up and run time parameters used
by the controller.
Mode Down/Up
MDU
Send one X/Y coordinate for each touchdown and
each liftoff on the touchscreen.
Mode Inactive
MI
Sends no X/Y coordinates when the screen is
touched.
Mode Point
MP
Sends a single X/Y coordinate for each touchdown.
Mode Polled
MQ
Sends an X/Y coordinate only when requested by the
host system and only when a user touches the screen.
Output Status
OS
Causes the controller to report the status of its
hardware.