miface PB

 

Universal Interface Profibus DP / Serial Interface RS232/485/422

 

 

Page

 

10

  
 

microSYST Systemelectronic GmbH, Albert-Einstein-Straße 7, 92637 Weiden 
Tel. +49 961 39166-0, Fax +49 961 39166-10, www.microsyst.de, [email protected] 

 

 

 

3.2  Connectors 

 

Power Supply 

 

Pin 

Assignment 

+12…+30 VDC 

GND 

PE 

 

 

RS 
 

Pin 

RS232 

RS485 

RS422 

RxD 

 

 

TxD 

 

 

GND 

GND 

GND 

 

Rx/Tx + 

Rx + 

 

Rx/Tx - 

Rx - 

 

 

Tx + 

 

 

Tx - 

PE 

PE 

PE 

 

See chapter „Settings“ for interface selection. 

 
 

Profibus DP 
 

Pin 

Assignment 

 

 

Rx+ / Tx+ 

RTS 

GND, electrically isolated 

+5V,  electrically isolated 

 

Rx- / Tx- 

 

 
 

Summary of Contents for miface PB

Page 1: ...melectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de miface PB Universal Interface Profibus DP Serial Interface RS232 485 42...

Page 2: ...DATA 3 2 1 Profibus DP Interface 4 2 1 1 Characteristic Data 4 2 1 2 DP Configuration Data 5 2 1 3 DP Diagnosis Data 6 2 1 4 DP Parameter Data 6 2 1 5 DP Output Data 6 2 1 6 DP Input Data 6 2 2 Transm...

Page 3: ...laid out for top hat rail mounting Settings for bus termination address and options can be made simply by using DIP switches 2 Technical Data Specifications Interface 1 Profibus DP Baud rate 9 6 kBaud...

Page 4: ...ce 2 1 1 Characteristic Data ID Number 05D0h GSD File MICR05D0 GSD Cyclical User Data max 200 bytes output max 200 bytes input max 300 bytes output input Standard Configuration 2x 0x3F 32 input output...

Page 5: ...ation the user can individually adapt data width within the data transfer Data widths of 1 to 16 bytes maximum are possible By specifying these identifiers in any order the desired total data width is...

Page 6: ...abled and the slave must be reconfigured and parameterised Note Standard parametrisation is required and is normally installed by the utilised DP configurators 2 1 5 DP Output Data The interface suppo...

Page 7: ...duration can be estimated based upon frame length and baud rate Transmission duration max Frame length x 11 baud rate x 1 2 In addition the delay through the processing on the master side the Profibu...

Page 8: ...and the frame length n is entered as byte 2 length byte The toggle byte is also increased by 1 Thus only the toggle byte needs to be monitored at the Profibus side As soon as it s value has changed da...

Page 9: ...osyst de 3 Connector Pin Assignments Front Side Bottom Side 3 1 LEDs LED Status Meaning red FAULT ON no Profibus DP connection or RAM error if green LED OFF OFF Profibus DP connection established gree...

Page 10: ...ax 49 961 39166 10 www microsyst de info microsyst de 3 2 Connectors Power Supply Pin Assignment 1 12 30 VDC 2 GND 3 PE RS Pin RS232 RS485 RS422 1 RxD 2 TxD 3 GND GND GND 4 Rx Tx Rx 5 Rx Tx Rx 6 Tx 7...

Page 11: ...DIP5 DIP6 DIP7 RS232 ON OFF OFF OFF OFF OFF OFF RS422 without bus termination OFF ON OFF OFF OFF OFF ON RS422 with bus termination OFF ON OFF OFF ON ON ON RS485 without bus termination OFF ON ON ON OF...

Page 12: ...7 N 2 ON ON Receive Timeout DIP 6 Baud Rate Receive Timeout short OFF 1200 Baud 29 ms 2400 Baud 16 ms 4800 Baud 9 ms 9600 Baud 6 ms 19200 Baud 4 ms 38400 Baud 3 ms 57600 Baud 3 ms 115200 Baud 3 ms lon...

Page 13: ...tely visible defects have to be indicated immediately after their perception too Generally defects and their symptoms must be described as accurately as possible in order to allow for reproducibility...

Page 14: ...r Albert Einstein Stra e 7 92637 Weiden Das bezeichnete Produkt stimmt mit der folgenden Europ ischen Richtlinie berein We herewith confirm that the above mentioned product meets the requirements of t...

Page 15: ...Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de 4 3 Versions Overview Version Date Comments 1 00 1 10 1 20 1 30 2012 09 17 2013 03 26 2013 10...

Reviews: