Technical Description
miriac MPX-LX2160A User Manual
V1.4
19/73
© MicroSys Electronics GmbH 2020
Two value types can be seen. One is the 'Cyclic updated Sensor' value, which are
the values monitored by the ME during runtime. The Register Values are the
values read during this command execution.
=> power_cfg
ISL68301 Power Switch Information:
ISL Device 0:
I2C Address = 0x68
DEVICE_ID = 0x49a02f00
Cyclic updated Sensor values:
VOUT nominal = 0.849V
VOUT trim = 0.000V
VIN = 12.312V
VOUT = 0.848V
IIN = 0.356A
IOUT = 4.546A
PIN = 4.476W
POUT = 3.847W
Register values:
OPERATION = 0x80
ON_OFF_CONFIG = 0x1e
VOUT_COMMAND = 0.849 V
READ_VOUT = 0.848 V
READ_IOUT = 4.445 A
VOUT_TRIM = 0.000 V
VOUT_MAX = 0.920 V
VOUT_OV_FAULT_LIMIT = 0.934 V
VOUT_OV_WARN_LIMIT = 0.917 V
VOUT_UV_FAULT_LIMIT = 0.658 V
VOUT_UV_WARN_LIMIT = 0.722 V
VIN_OV_FAULT_LIMIT = 16.000 V
VIN_OV_WARN_LIMIT = 15.500 V
VIN_UV_FAULT_LIMIT = 4.500 V
VIN_UV_WARN_LIMIT = 4.796 V
IOUT_OC_FAULT_LIMIT = 30.000 A
IOUT_OC_WARN_LIMIT = 21.000 A
IOUT_AVG_OC_FAULT_L = 24.000 A
READ_TEMPERATURE_1 = 47.750 C
READ_TEMPERATURE_2 = 0.000 C
READ_TEMPERATURE_3 = 46.562 C
FREQUENCY_SWITCH = 500.000 KHz
READ_FREQUENCY = 500.000 KHz
ISL Device 1:
I2C Address = 0x69
DEVICE_ID = 0x49a02f00
Cyclic updated Sensor values:
VOUT nominal = 0.849V
VOUT trim = 0.000V
VIN = 12.312V
VOUT = 0.848V
IIN = 0.359A
IOUT = 4.570A
PIN = 4.398W
POUT = 3.843W
Register values:
OPERATION = 0x80
ON_OFF_CONFIG = 0x1e
VOUT_COMMAND = 0.849 V
READ_VOUT = 0.849 V
READ_IOUT = 4.515 A
VOUT_TRIM = 0.000 V
VOUT_MAX = 0.920 V
VOUT_OV_FAULT_LIMIT = 0.934 V
VOUT_OV_WARN_LIMIT = 0.917 V
VOUT_UV_FAULT_LIMIT = 0.658 V
VOUT_UV_WARN_LIMIT = 0.722 V
VIN_OV_FAULT_LIMIT = 16.000 V