Technical data

blind zone

operating range

maximum range

angle of beam spread

20 mm
150 mm

30 mm
250 mm

250 mm
see detection zone

350 mm
see detection zone

transducer frequency

resolution

reproducibility

detection zones

for different objects:

The dark grey areas represent the zone 

where it is easy to recognise the normal 

reflector (round bar). This indicates the typical 

operating range of the sensors. The light 

grey areas represent the zone where a 

very large reflector – for instance a 

plate – can still be regognized. The 

requirement here is for an optimum 

alignment to the sensor. It is not 

possible to evaluate ultrasonic 

reflections outside this area. 

380 kHz
0.069 mm

320 kHz
0.069 mm

± 0.15 %

± 0.15 %

accuracy

operating voltage U

B

voltage ripple

no-load current consumption

±1 % (temperature drift internally compensated)
10 - 30 V DC, reverse polarity protection (Class 2)

±1 % (temperature drift internally compensated)
10 - 30 V DC, reverse polarity protection (Class 2)

±10 %
< 40 mA

±10 %
< 40 mA

housing

ECOLAB

class of protection per EN 60 529

stainless steel 1.4404/316L;
ultrasonic transducer: PTFE, FKM

stainless steel 1.4404/316L;
ultrasonic transducer: PTFE, FKM

yes
IP 67

yes
IP 67

norm conformity

type of connection 

controls

EN 60947-5-2

EN 60947-5-2

4-pin M8 initiator plug
Teach-in via pin 2 (Com)

4-pin M8 initiator plug
Teach-in via pin 2 (Com)

programmable

operating temperature

storage temperature

switched output

Teach-in, LinkControl
-25°C to +70°C

Teach-in, LinkControl
-25°C to +70°C

-40°C to +85°C
Push-Pull, U

B

-3 V, -U

B

+3 V,  I

max

 = 100 mA

-40°C to +85°C
Push-Pull, U

B

-3 V, -U

B

+3 V,  I

max

 = 100 mA

switching hysteresis 

1)

switching frequency 

1)

response time 

1)

switchable NOC/NCC, short-circuit-proof
2 mm

switchable NOC/NCC, short-circuit-proof
3 mm

25 Hz
32 ms

25 Hz
32 ms

time delay before availability 

1)

weight

order no.

< 300 ms
30 g

< 300 ms
30 g

pms-15/CF/A1

pms-25/CF/A1

1) Can be programmed with LinkControl

65 mm
350 mm

120 mm
1,000 mm

600 mm
see detection zone

1,300 mm
see detection zone

400 kHz
0.069 mm

200 kHz
0.069 mm

± 0.15 %

± 0.15 %

±1 % (temperature drift internally compensated)
10 - 30 V DC, reverse polarity protection (Class 2)

±1 % (temperature drift internally compensated))
10 - 30 V DC, reverse polarity protection (Class 2)

±10 %
< 40 mA

±10 %
< 40 mA

stainless steel 1.4404/316L;
ultrasonic transducer: PTFE, FKM

stainless steel 1.4404/316L;
ultrasonic transducer: PTFE, FKM

yes
IP 67

yes
IP 67

EN 60947-5-2

EN 60947-5-2

4-pin M8 initiator plug
Teach-in via pin 2 (Com)

4-pin M8 initiator plug
Teach-in via pin 2 (Com)

Teach-in, LinkControl
-25°C to +70°C

Teach-in, LinkControl
-25°C to +70°C

-40°C to +85°C
Push-Pull, U

B

-3 V, -U

B

+3 V,  I

max

 = 100 mA

-40°C to +85°C
Push-Pull, U

B

-3 V, -U

B

+3 V,  I

max

 = 100 mA

switchable NOC/NCC, short-circuit-proof
5 mm

switchable NOC/NCC, short-circuit-proof
20 mm

12 Hz
64 ms

10 Hz
80 ms

< 300 ms
30 g

< 300 ms
30 g

pms-35/CF/A1

pms-100/CF/A1

+U

B

-U

B

F

1
2

4

3

Push-Pull output in pnp circuit

U

+U

B

-U

B

F

1
2

4
3

Push-Pull output in npn circiut

U

Com

Com

pms-15...

pms-25...

8  cm

4 cm

0 cm

4 cm

8 cm

0 cm

4 cm

8 cm

12 cm

16 cm

20 cm

24 cm

Rohr ø 10 mm

ausgerichtete Platte

Plate

Rohr ø 10 mm

8 cm

0 cm

4 cm

8 cm

4 cm

8  cm

4 cm

0 cm

4 cm

8 cm

0 cm

4 cm

8 cm

12 cm

16 cm

20 cm

24 cm

Rohr ø 10 mm

ausgerichtete Platte

Round bar ø 10 mm

8 cm

0 cm

4 cm

8 cm

4 cm

0 cm

4 cm

8 cm

12 cm

16 cm

20 cm

24 cm

0 cm

5 cm

10 cm

15 cm

20 cm

25 cm

30 cm

35 cm

Plate

Round bar ø 10 mm

10 cm

5 cm

0 cm

5 cm

10 cm

pms-35...

pms-100...

0 cm

10 cm

20 cm

30 cm

40 cm

50 cm

60 cm

Plate

Round bar ø 27 mm

20 cm

10 cm

0 cm

10 cm

20 cm

35 cm

0 m

0,2m

0,8 m

1,0 m

1,3 m

0,4 m

0 m

0,4 m

0,6 m

0,4 m

1,0 m

1,4 m

0,2 m

0,2 m

Round bar ø 27 mm

Plate

arrangement of the sensors shown
in figure 2 must be maintained. 

The pms sensors are equipped
with an internal temperature com-
pensation. Due to the sensors self
heating, the temperature compen-
sation reaches its optimum work-
ing-point after approx. 45 seconds
of operation.

In the »Set detect point – method
A« Teach-in procedure the actual
distance to the object is taught to
the sensor as the detect point. If
the object moves towards the
sensor (e.g. with level control) then
the taught distance is the level at
which the sensor has to switch the
output.

If the object to be scanned moves
into the detection area from the
side, the »Set detect point +8 % –
method B« Teach-in procedure
should be used. In this way the
switching distance is set 8 % fur-
ther than the actual measured dis-
tance to the object. This ensures a
reliable switching distance even if
the height of the objects varies
slightly. 

Fig. 4: Setting the detect point for different  

directions of movement of the object

The sensor can be reset to its fac-
tory setting (see »Further set-
tings«).

For Teach-in procedure when us-
ing the LinkControl adapter (op-
tional accessory) the additional
adapter 5G/M12-4G/M12/M8 is
needed.

If the sensor is cleaned wet during
operation, all surfaces must be in-
clined at least 3° from the hori-
zontal alignment so that the clea-
ning agents can run off completely
(see figure 3).