Operating Instructions

Ultrasonic proximity switch with
one switched output

pms+15/CF/A1
pms+25/CF/A1
pms+35/CF/A1
pms+100/CF/A1

Product description

The pms sensor has a stainless steel
housing and is designed for applica-
tions with hygienic requirements.
The ultrasonic transducer surface of
the pms sensors is laminated with a
PTFE film. The transducer itself is
sealed against the housing by a joint
ring. 
The pms sensor with D12 adapter
shaft can be fitted in a mounting clip
which meets hygiene standards like
the sensor srew connection BF-pms/
A1.
The special housing design ensures
that any cleaning fluids are able to
run off completely, regardless of the
installation situation. 
The pms sensor is ECOLAB certified.
The pms sensor variant D12 adapter
shaft offers a non-contact measure-

Sensor adjustment with Teach-in procedure

Set detect point

– method A

Place object at position 

 

Connect Com for about 

3 s to +U

B

Set detect point +8 %

– method B

Place object at position 

 

Connect Com for about 

3 s to +U

B

Set window mode

Set two way reflective

barrier

Set NOC/NCC

Place object at position 

 

Install reflector at 

position 

 

Connect Com for about 

3 s to +U

B

Connect Com for about 

3 s to +U

B

Connect Com for about

13 s to +U

B

Reset to factory setting

Switch off operating 

voltage

Connect Com to -U

B

Switch on 

operating voltage

Keep Com connected to 

-U

B

 for about 13 s

Connect Com for about 

1 s to +U

B

Normal operating mode

Connect Com for about 

3 s to +U

B

Place object at position 

 

Connect Com for about 

1 s to +U

B

Connect Com for about

10 s to +U

B

To change output 

characteristic connect 

Com for about 1 s to +U

B

 

Wait for 10 s

Disconnect Com from -U

B

before switching off supply

voltage

Normal operating mode

ment of the distance to an object
present within the sensors's detec-
tion zone. The switched output is set
conditional upon the adjusted detect
distance.
For sensor setting, the accessory
LinkControl adapter LCA-2 is recom-
mended in combination with Link-
Control software for Windows©. Al-
ternatively, the sensor can also be set
by Teach-in via pin 2. 
The pms sensors are IO-Link-capable
in accordance with IO-Link specifica-
tion V1.1.

Safety Notes

Read the operating instructions
prior to start-up.

Connection, installation and ad-
justment works should be carried
out by expert personnel only.

No safety component in
accordance with the EU Machine
Directive.

Proper Use

pms ultrasonic sensors are used for
non-contact detection of objects.
The sensor must be mounted in an
EHEDG-approved mounzing clip,
such as the sensor screw connection
BF-pms/A1 for a EHEDG-complaint
use. 

Installation

Assemble the sensor and its hygi-
enic D12 sensor screw connection
BF-pms/A1 or an equivalent sensor
mounting clip at the instation lo-
cation.

Pull sensor cable through the sen-
sor gland, connect it to the M8

sensor plug.

Push the sensor with its shaft into
the sensor screw connection BF-
ms/A1 and adjust (see figure 4-6).
Tighten with lock nut (maximum
tightening torque 12 Nm).

 Fig. 1: Pin assignment with view onto sensor 

plug and colour coding of the

        microsonic connection cables

Start-up

Connect the power supply.

Carry out sensor adjustment with

1

3

colour

+U

B

-U

B

brown

blue

4

2

F

Com

black

white

1

5

2

3

4

LinkControl or alternatively Teach-
in procedure in accordance with
the diagram.

Factory Setting

Detect point operation

Switched output on NOC

Detect distance at operating range

Filter at F01

Filter strength at P00

Operating Modes

Three operating modes are available
for the switched output:

Operation with one detect point

The switched output is set when the
object falls below the set detect
point.

Window mode

The switched output is set when the
object is within the set window.

Two-way reflective barrier

The switched output is set when the
object is between sensor and fixed
reflector.

Fig. 2:  Assembly distances

Maintenance

microsonic sensors are maintenance-
free. For cleaning in areas with hygi-
enic requirements, access to the sen-
sor must be guaranteed from all
sides. Cleaning is permitted up to a
cleaning temperature of 85°C. Do
not use a high-pressure cleaner to
clean the sensor. 

Notes

The sensors of the pms family
have a blind zone, within which a
distance measurement is not pos-
sible.

If several pms sensors are operated
in a small space, the minimum
mounting for parallel or opposite

pms-15

pms-25

pms-35

0.25 m

1.30 m

0.35 m

2.50 m

0.40 m

2.50 m

pms-100

0.70 m

4.00 m

Set switched output