DOC 4380A
4380A O & M Manual
75
098-00723-000
– Jul 2017 Revision 4.0
SyncSystem 4380A O&M Manual
Jun 15 13:30:52 Sync System Sync System[536]: .048 0x0060e900 [KAS2] System time is
valid, starting KAS2 processing
Jun 15 13:30:52 Sync System Sync System[536]: .052 0x00643d00 [Engine] Thread
Log::Manager starts
Jun 15 13:30:52 Sync System Sync System[536]: .319 0x0060e900 [KAS2] Reference is locked
and system time is valid, starting KAS2 processing
Jun 15 13:30:52 Sync System Sync System[536]: .317 0x00678100 [Engine] Thread ensemble
starts
Jun 15 13:30:54 Sync System Sync System[536]: .064 0x00587f00 [Ntp] Starting NTPD
Error Logs:
After startup the system tracks all events and alarm conditions (asserted) and when those
alarms cleared (cleared) as they occurred in chronological order.
Jun 15 13:30:55 Sync System Sync System[536]: .350 0x00587f00 NtpPipeWriter: change in
leap second info, mLeapCurr now 24 was 0, mLeapPend now 0 was 0
Jun 15 13:30:55 Sync System ntpd[555]: ntpd 4.2.0-a Fri Jun 11 16:51:53 UTC 2010 (1)
Jun 15 13:30:55 Sync System ntpd[555]: precision = 84.267 usec
Jun 15 13:30:55 Sync System ntpd[555]: no IPv6 interfaces found
Jun 15 13:30:55 Sync System ntpd[555]: kernel time sync status 2040
Jun 15 13:30:55 Sync System ntpd[555]: Starting tsc ntp reference clock
Jun 15 13:31:46 Sync System ntpd[555]: synchronized to REFCLK(25,0), stratum=0
Jun 15 13:32:49 Sync System ntpd[555]: synchronized to REFCLK(25,0), stratum=0
Jun 15 13:32:56 Sync System Sync System[536]: .784 0x00643300 NTP has locked
Jun 15 13:32:56 Sync System Sync System[536]: .793 0x00643300 [Sync SystemHardware]
Turning on hardware outputs
6.18 System Configuration Issues (syscfg)
Operators can set the system up to report set up or installation errors (i.e. a card in the wrong slot). When
set up properly and enabled the system can report errors made in the system settings so operators are able to
quickly detect set up errors, system errors, and if a card is in the wrong slot or the incorrect card was
installed in a slot.
For a complete list of the configuration errors detected by the system use the
status syscfg:errors
command.
If the errors are not correct you may need to edit the configuration files.
Factory Default: /usr/tsc/syscfg/syscfg_default.py. This file should not be edited. These are the factory
default settings for the unit. If necessary you can use this file as a reference guide.
User File: /mod/tsc/syscfg/localcfg.py
Summary of Contents for SyncSystem 4380A
Page 2: ......