DOC 4380A
4380A O & M Manual
39
098-00723-000
– Jul 2017 Revision 4.0
SyncSystem 4380A O&M Manual
4.
Once the update is complete the system will automatically reboot. Local users will see the
front panel display lock up for ~2 minutes. After this the system will begin launching the
application and local users will see the typical boot process. The application start up will take
~2 minutes. Once the SYNC light is on it will take an additional 1.5 to 2 minutes for NTP to
lock and for the outputs to be enabled.
Users can obtain the new software image and software release notes from Microsemi
>Products > Time & Frequency Distribution > GPS Instruments >
SyncSystem 4380A > Documents .
Refer to the Software Release Notes for specific instructions related to
a particular revision of software.
CAUTION
If the software update is not applied and the unit is power cycled users will need to upload the .iso file
again in order to update the system software. The .iso file will be wiped from the system since it is held in
volatile memory.
Si la mise à jour de logiciel n'est pas appliquée et l'unité est les utilisateurs faits un cycle par puissance
devra télécharger le dossier de .iso encore afin de mettre à jour le logiciel système. Le dossier de .iso sera
essuyé du système puisqu'on le tient dans la mémoire volatile.
3.3.3 GPS Firmware Updates
Updating the firmware on the GPS receiver requires that the GPS receiver be removed from the system,
updated, and reinstalled. The GPS Firmware version can be checked using the
status gps:model
command.
4380A>status gps:model
[hw_version] OEMV3G-4.01-X2T
[name] L12LV
[serial_number] DAB08410131
[sw_version] 3.803
[OK] 2015-08-05T21:07:04Z
3.4 User Interfaces
Software interfaces on the 4380A are limited in their ability to provide users with real-time control.
Adjusting some system parameters during operation of the 4380A can seriously impact the timing
performance of the unit and therefore the ability to adjust these parameters is limited by the software. Once
properly installed, the 4380A serves as a stand-alone device which requires little to no interaction. Remote
error monitoring capabilities are provided as a means to ensure that the unit is powered and operating
properly.
3.4.1 Telnet
One advantage of accessing the 4380A via telnet is that multiple telnet sessions may be active at once. It is
recommended that users connect directly to the desired port based on the function(s) they are going to
perform.
1135 Real Time Logging
1700 Command
1800 Diagnostics
1900 Status
2100 Average TIC Data (4393A Card)
2101 Raw TIC Data (4393A Card)
Summary of Contents for SyncSystem 4380A