Recommended Tasks
Microsemi recommends the user configure the SyncServer S80 before mounting it in its outdoor or
rooftop location.
1. Make a temporary connection between the SyncServer S80 and the desired network. Refer to
for placement of the PoE midspan repeater.
2. Establish an SSH connection from your computer to the IP address assigned to the SyncServer
S80.
Note:
The S80 default IP address is 192.168.100.11, the subnet mask is 255.255.255.0, and the gateway
address is 0.0.0.0 (no gateway).
Note:
The Ethernet interface must be 1000 Base-T. Lower speed connections are not supported.
3. Type the default user name admin and press Enter.
4. Type default password Microsemi and press Enter. The system prompt will appear.
Note:
Microsemi recommends using a static IP address. Whenever any IP address or mode is changed,
the S80 must be rebooted. Users are not recommended to use DHCP for the SyncServer S80
because there is no convenient method for retrieving assigned DHCP address for the management
port after reboot.
5. Set the desired IPv4 or IPv6 address using the
set ip
command.
IPv4 Example
To set the static IPv4 address for the Ethernet Interface to 192.168.2.11, the mask to 255.255.255.0,
and the gateway 0.0.0.0:
S80> set ip ipv4 ip-address 192.168.2.11 netmask 255.255.255.0 and gateway
0.0.0.0:
S80> set ip ipv4 ip-address 192.168.2.11 mask 255.255.255.0 gateway 0.0.0.0
S80> set ip ipv4 state enable
S80> set ip ipv4 state restart
IPv6 Example
To set the static IPv6 address for the Ethernet Interface to 2201:db8:1234::11 , the prefix to 64, and
the gateway 2201:db8:1234::1:
S80> set ip ip6 ip-address 2201:db8:1234::11 prefix 64 gateway 2201:db8:1234::11
S80> set ip ipv6 state enable
S80> set ip ipv6 state restart
Caution:
Microsemi strongly recommends that you record the serial number, hostname and MAC of
the SyncServer S80 before installing it.
Table 2-3 •
Record Important System Settings and Values
Parameter
Value
IPv4 Address
IPv4 Prefix
IPv4 Default Router
IPv6 Address
IPv6 Prefix
IPv6 Default Router
MAC Address
Serial Number
Hostname
Summary of Contents for SyncServer S80
Page 1: ...SyncServer S80 NTP Server User Guide Part Number 098 00777 000 Revision A...
Page 2: ...SyncServer S80 NTP Server...
Page 6: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 6...
Page 24: ...Installation of SyncServer S80 24 098 00777 000 Rev A Figure 2 15 Surge Protector Dimensions...
Page 25: ...SyncServer S80 NTP User Guide 098 00777 000 Rev A 25 Figure 2 16 Connecting Surge Protector...
Page 50: ...CLI Commands 50 098 00777 000 Rev A...