PDS-104G PoE Switch
Power Over Ethernet PowerView Pro User Guide
Copyright © 2016
Microsemi
Page 30 of 48
Rev. 1.0
CPG
– PoE BU
One Enterprise Aliso Viejo, CA 92656 USA
Reset only Network Manager
Reset only the internal Network Manager which is responsible for unit
network management interfaces such as Web, Telnet/SSH, SNMP, etc.
Internal Ethernet switch will also be reset (the network will be down for a
few seconds) leaving PoE power unchanged (powered PD devices will
continue normal operation as if no reset was done).
Reset unit
Reset the entire unit including the internal Network Manager, the PoE
controller, and the internal Ethernet Switch.
Enable/Disable auto ping to
Default Gateway to ensure
network connectivity
When enabled, the unit will verify proper network connectivity by pinging
default gateway every 12 seconds (IPv4 DGW or IPv6 DGW). After 10
consecutive ping failures, Network Management Module will reset itself
without affecting PoE ports.
NOTE:
To simplify finding the unit over the network, upon power up the unit will send SysLog
broadcast messages to IP 255.255.255.255 to all SysLog servers on the Network reporting its IP
network configuration parameters, its MAC address, host name, etc