Microsemi PDS-104G User Manual Download Page 15

PDS-104G PoE Switch 

Power Over Ethernet PowerView Pro User Guide 

 
 

Copyright © 2016 

Microsemi

 

 

Page 15 of 48

 

Rev. 1.0 

CPG 

– PoE BU 

 

One Enterprise Aliso Viejo, CA 92656  USA 

 

 

 

Figure 

‎3-7: Security Configuration 

 

User Name 

Unit user name for remote Web/Telnet/SSH access 

Password 

Unit password for remote Web/Telnet/SSH access 

Telnet/SSH 

Enable remote login via Telnet or SSH  

Web Encryption 

Force all web pages to become encrypted over SSL/TLS 

 
 

3.3.3  Network Configuration 

Configure unit IPv4, IPv6 and host name parameters.  

 

Figure 

‎3-8: Network Configuration 

3.3.3.1  IPv4 Network Configuration 

Enable DHCPv4 

Obtain IPv4 address from DHCPv4 Server 

IPv4 Address 

Static IPv4 address whenever DHCPv4 is off 

IPv4 Subnet Mask 

Static IPv4 mask whenever DHCPv4 is off 

IPv4 Default Gateway 

Static IPv4 default gateway whenever DHCPv4 is off 

 

3.3.3.2  IPv6 Network Configuration 

 

Summary of Contents for PDS-104G

Page 1: ...Microsemi Outdoor PDS 104G PoE Switch PowerView Pro User Guide...

Page 2: ...CA 92656 USA Acknowledgements All other products or trademarks are property of their respective owners The product described by this manual is a licensed product of Microsemi Abbreviations and Termin...

Page 3: ...2 3 Main Web Page Ports Status Reset 13 3 3 CONFIGURATION WEB PAGE 14 3 3 1 First Time Configuration 14 3 3 2 Security Configuration 14 3 3 3 Network Configuration 15 Configure unit IPv4 IPv6 and hos...

Page 4: ...LOAD UNIT CONFIGURATION OVER TFTP 37 7 1 UPLOAD UNIT CONFIGURATION TO TFTP SERVER 37 7 2 DOWNLOAD UNIT CONFIGURATION FROM TFTP SERVER 38 8 SOFTWARE UPDATE 39 8 1 NETWORK MANAGER SOFTWARE UPDATE 39 8 1...

Page 5: ...is an outdoor PoE switch that enables connecting four powered devices to the network The switch will deliver PoE power per device up to 60W for ports 1 2 and up to 30W for ports 3 4 In addition it en...

Page 6: ...following table CONVENTION DEFINITION bold Keywords and commands italics Represents a Web interface item screen Displayed Information Courier text Information to be entered Notes Helpful information 1...

Page 7: ...E Switch Power Over Ethernet PowerView Pro User Guide Copyright 2016 Microsemi Page 7 of 48 Rev 1 0 CPG PoE BU One Enterprise Aliso Viejo CA 92656 USA SysLog System Log SFP Fiber interface small form...

Page 8: ...ptions o HTTP Web based friendly configuration interface for managing remote Outdoor Power over Ethernet device o HTTPS SSL TLS Secured Web based friendly configuration interface for managing remote O...

Page 9: ...llowing PoE options are available Two 4Pair PoE Ports Delivers up to 60 watts per port Two IEEE 802 3at Delivers up to 30 watts per port PoE Enable Disable Enable disable PoE ports power output Ethern...

Page 10: ...ice SNMP v3 Resolves SNMPv1 v2 security issues by adding authentication and encryption to layer on top of SNMP packets 2 7 Default unit IP username and password The unit is shipped with the following...

Page 11: ...d SSL TLS Web interface handling certificates Please refer to document PDS 104G Web Certificate Management for instructions on how to create sign and upload self signed or CA signed certificates to th...

Page 12: ...power is provided upper power indicator is on Ethernet link is on low link indicator image is green PoE port is disabled RJ45 connector marked by two red lines No Ethernet link lower link indicator im...

Page 13: ...n Web Page Ports Status Reset Figure 3 4 Ports Status Reset Network reports for each port Ethernet link speed 10 100 1000MB and if the Network connection is up or down Status reports for each port the...

Page 14: ...password is password Selecting the Configuration option on the menu will reveal the unit configuration Web page Please change the unit remote access username and password to other then admin password...

Page 15: ...nable remote login via Telnet or SSH Web Encryption Force all web pages to become encrypted over SSL TLS 3 3 3 Network Configuration Configure unit IPv4 IPv6 and host name parameters Figure 3 8 Networ...

Page 16: ...terminology as host name 3 3 4 Network Services Configuration IPv4 IPv6 Figure 3 9 Network Services Configuration DNS Server 1 DNS Server 2 Domain Name Server IPv4 IPv6 address Please note that DNS fi...

Page 17: ...SNMPv2 SET community string For example private SNMPv2 TRAP Community SNMPv2 Trap community string For example public MIB II SysContact SNMP MIB II system contact OiD string For example John MIB II S...

Page 18: ...no encryption similar to MD5 only using different authentication algorithm MD5 DES authentication is done by MD5 while encryption is done by DES SHA DES authentication is done by SHA while encryption...

Page 19: ...traffic through the various ports o Reset Unit Reset the internal Network Manager internal PoE controller and internal Ethernet Switch o Reset to Factory Default Reset unit configuration to factory d...

Page 20: ...ore PoE ports can be assigned to each PoE activation scheme NOTE For Automatic Weekly Schedule PoE Port Activation to function properly an NTP Server must be configured see Configuration Web Page prov...

Page 21: ...y Schedule PoE Port Reset to function properly an NTP Server must be configured see Configuration Web Page providing correct GMT time Please make sure that a green OK appears to the right of the unit...

Page 22: ...IP IP Address etc maintaining the option to access the unit over the network as before NOTE To simplify finding the unit over the network upon power up the unit will send SysLog broadcast messages to...

Page 23: ...ble for converting URL names such as my computer com to IPv4 IPv6 addresses DNS 2 Alternate in use second DNS to be used in case the first DNS is down 3 5 1 3 Information Web Page In Use IPv6 Address...

Page 24: ...ork Manager software version Firmware Version Unit PoE firmware version responsible for PoE functionality Boot Version NMS Boot version MAC Address Unit MAC addresses A unique 6 byte number used for E...

Page 25: ...elnet SSH user tries to access the unit while the first Telnet SSH session is still active a short message will appear to the second Telnet SSH user requesting the user to try and reconnect over Telne...

Page 26: ...ew Menu 4 2 1 Telnet SSH View PoE Ports Status View PoE ports status provides Network plus PoE power consumption information for each one of the ports plus overall power consumption and internal power...

Page 27: ...rk Reports if DHCPv4 is enabled or disabled and the actual in use IPv4 address IPv4 mask and default gateway In use IPv6 Network Parameters Reports if DHCPv6 is enabled or disabled and the actual in u...

Page 28: ...mber Unit six digit serial number Production Number Unit production number for internal use only App Ver Network Manager software version Boot Version Network Manager Boot version Firmware PoE firmwar...

Page 29: ...owever network traffic may be interrupted for several seconds while the internal Ethernet Switch is reinitialized Upload configuration file to TFTP Server Upload unit configuration file from unit to T...

Page 30: ...reset was done Reset unit Reset the entire unit including the internal Network Manager the PoE controller and the internal Ethernet Switch Enable Disable auto ping to Default Gateway to ensure network...

Page 31: ...ith the SNMPv2 v3 disabled Prior to enabling SNMP please modify SNMP community strings and only then enable it 5 1 Enabling SNMP The Network Manager interface supports SNMPv1 SNMPv2c and SNMPv3 since...

Page 32: ...Notification Privacy Password password SNMPv3 Notification Authentication and Encryption Mode None SNMPv3 Notification Table 5 1 Default SNMP usernames and passwords 2 Traps To enable traps set remote...

Page 33: ...re 5 3 Unit supported SNMP MIB s 5 3 RFC3621 PoE MIB NOTE For a detailed PoE MIB description please refer to Microsemi s Technical Note 132 which describes in detail PoE MIB functionality RFC3621 PoE...

Page 34: ...A Figure 5 4 MIB Tree Structure 5 4 Private MIB The following SNMP OiDs are supported by the SNMP private MIB OiD Name Type R W Description poePortConsumptionPower R PoE port power consumption Watt po...

Page 35: ...s that may be sent by the SysLog Server Table 2 SysLog Message Types Msg ID Description Information to be provided Comments 0 System UP Will be sent each time power is provided to the unit or the inte...

Page 36: ...y Telnet Telnet SSH with incorrect username password Remote user IPv4 IPv6 address 12 DHCPv4 Will be sent only upon the 1 st first time DHCPv4 address was obtained either by switching from static to D...

Page 37: ...rejected please see the message below 2 For offline configuration changes please contact tech support at poesupport microsemi com 7 1 Upload Unit Configuration to TFTP Server Use the following procedu...

Page 38: ...with the unit see Upload Unit Configuration but this time select Download configuration file from TFTP Server Figure 7 2 Download Unit Configuration 3 Type the TFTP Server IPv4 IPv6 address file name...

Page 39: ...e Network Manager provides the graphical Web textual Telnet SSH SNMP interface between the unit and the remote Network user excluding PoE functionality which is performed by a dedicated Micro Controll...

Page 40: ...and only then does the actual software update starts The Telnet SSH session will be lost during to the software update process However PoE power will remain during the entire software update process...

Page 41: ...ry procedure 2 remote TFTP Server 192 168 0 50 In case unit fail to re initiate software update from remote TFTP Server as it was instructed prior power loss for example TFTP Server IP is no longer va...

Page 42: ...enance Menu 5 Select Software update menu Figure 8 3 Selecting Software Update from the Configuration Menu 6 Select Update Unit Manager module software and type the TFTP Server IP Address see image be...

Page 43: ...rnet PowerView Pro User Guide Copyright 2016 Microsemi Page 43 of 48 Rev 1 0 CPG PoE BU One Enterprise Aliso Viejo CA 92656 USA of the firmware update the unit will reset itself re power PD devices an...

Page 44: ...completely off 4 Apply back power to the unit And wait around 30 seconds 5 The entire procedure described below should be done in less than 120 seconds since power was applied to the unit 6 Connect to...

Page 45: ...Windows 7 Click Start and type cmd For Windows 8 Press the Windows key R key and type cmd 5 Type ipconfig to identify the virtual interface index of your IPv6 Link Local address 17 in the image below...

Page 46: ...t session on TCP port 2525 Please note that the time window for password recovery is limited to 120 Sec since power up 8 Type passwordrecovery as username and passwordrecovery as password A recovery o...

Page 47: ...he Unit Ping utility to ping the host running the TFTP Server application 2 Turn off firewall or enable UDP port 69 3 Verify that the appropriate update files package was copied to the TFTP Server roo...

Page 48: ...itical equipment or applications Microsemi assumes no liability whatsoever and Microsemi disclaims any express or implied warranty relating to sale and or use of Microsemi products including liability...