12. CONTROL BOARD FIRMWARE UPDATE (*)
By using a firmware update file provided by Micronova, you can update the control
board’s operating software with a personal computer and the
SERAMI
software
with a serial connection to the control board and the relative RS232 interface.
A.
Remove the electrical power from the control board.
Connect the serial cable from the RS232 interface. It must be connected correctly to
the personal computer with the serial port correctly configured with the
SERAMI
.
B.
From the “INSTRUMENTS” menu and from the following “UPDATE
FIRMWARE” submenu, access the procedure according to the instructions
listed below.
C.
Select the
ATMEL
option.
D.
Select the file containing the stove’s operating program, see
figure 39
.
E.
Select the “START” button and wait for the message that reads “
Shut off and
turn on the control board
”. Power the control board and wait for the progress
bar to fill up.
F.
Select the “CLOSE” button to exit the procedure.
After completing the update you must load the values of one of the databases in
order to assign consistent values to the parameters, see paragraph 10.2.
If you do not have a
SERAMI
(.snet) configuration file, access the
“APPLICATIONS” page on the Micronova website to download the file.
From here, find “
Download SeramiNet configuration file
” and type the exact name
of the ENC file without the extension.
For example, if the ENC file is called “MY_FIRMWARE.ENC”, type
“my_firmware” (not case sensitive) and select the “SEND QUERY” button.
Contact Micronova if the download is not available.