Micronova S.r.l.
-
Via A. Niedda, 3
-
35010 Vigonza (PD)
-
+39 049 8931563
-
+39 049 8931346
date 11/06/2016
page 45 of 83
Control board L023
Micronova
ENG
OPERATING
MODE
SHUT DOWN
OFF
REIGNITE
U
S
E
R
O
P
E
R
A
T
IN
G
M
O
D
E
8.10 Switching off the stove
To switch off the stove simply press the P4 button for about 2
seconds.
The auger is immediately stopped and the flue is brought to high
speed.
The FINAL CLEANING phase is carried out.
The flue is disabled once the Pr39 time has elapsed after the flue
temperature has fallen under that of the Pr28 setting.
fig. 24
8.12 Reigniting the stove
It won’t be possible to reignite the stove until the flue temperature
falls under the temperature indicated by the Pr13 setting and a safe
amount of time has passed indicated by the Pr38 setting.
fig. 22
8.11 Stove in off mode
.
fig. 23