ES-
50
Elevation Stage
Rev: 3.05
14
Reference Manual
MICRONIX USA,LLC
www.micronixusa.com
6.2
Limit Switches
The limit switches are normally closed (when not activated) and should be
connected to a compatible controller that recognizes these settings. Failure to
properly set up the limit switches in the controller will result in physical damage to
the switches themselves. A hard stop is designed into the ES-50 body which will
prevent the carriage from running away should the limit switches fail.
The limit switches are factory calibrated to ensure advertised travel length and
cannot be adjusted by the customer. For custom travel lengths, please contact
MICRONIX USA.
6.2.1
Mechanical Limit Switches
Contact Rating
100 mA @ 30 V
Contact Type
Normally Closed
Operating Temperature -25 to +70 °C
6.2.2
Limit Switch Schematic
6.2.3
Direction of Motion
Limit Switch
Common
- Limit Switch
+ Limit Switch
+ Limit
- Limit
Positive Direction