MICRON

3. Input the factory default lock setting of “010” by incrementing the “

5

” key. 

4. Press SET key again and the display will show F-0 and flash. There are 3 parameters that can be set.

Parameter F-1 is temperature lock setting.
Parameter F-2 is temperature correction setting.
Parameter F-3 is to change between Fahrenheit and Centigrade (Celsius) temperature selection

5. To select parameter setting, press the “

5

” or “

6

” to scroll through to the parameter setting you desire set.

Note that the unit returns to normal operation after 15 seconds if no key is pressed.

TEMPERATURE ADJUSTMENT LOCKOUT SETTING

When the LED displays “F-1” and flashes, press “SET” key and the unit enters the temperature adjustment
lockout status. At this moment, the LED displays the preset value. If “000” is set, this means the unit has no
temperature lock. 

Press “

5

” or “

6

” key to change temperature adjustment lockout value. The temperature adjustment lockout

is number “100”. Once the number is entered, press “SET” key again to finish setting.

The user can now continue to set other parameters. 

TEMPERATURE CORRECTION SETTING 

When the LED displays “F-2” and flashes, press “SET” key to enter Temperature Correction Mode. At this
moment, the LED displays preset correction value. 

A: 

Centigrade temperature corr99°C ~-99°C 

Press “

5

” or “

6

” key to change the temperature correction amount. If the temperature on the display is

more than the temperature of the tip, input a positive figure. Eg If the current display set temperature is
200°C, the actual temperature of the tip is only 190°C, and the temperature offset is 00, enter +10°C. 

If there is already a temperature offset, then increment the temperature offset by +10°C. That is, if the offset
temperature is already 5°C, then the new temperature offset will be 15°C 

If the temperature on the display is less than the temperature of the tip, enter a negative figure by pressing
the “

6

” key until the desired amount is displayed. 

The first digit will display “— ” (minus). 

B:

Fahrenheit temperature correction value +210°F ~-210°F 

Fahrenheit temperature correction is the same as above, except that the adjustment can be up to 3 digits,
and the negative symbol will not display. 

FAHRENHEIT AND CENTIGRADE (CELSIUS) TEMPERATURE SELECTION 

When the display shows "F-3" and is flashing, press the "SET" button. The display will show the current setting
- for Celsius °C: or Fahrenheit: °F. To change the temperature selection setting, press “

5

” or “

6

” key. To save

the setting, press SET key.

RECOMMENDED SOLDERING WORKING TEMPERATURES. 

A low iron temperature will slow the flow of solder. A high temperature will burn the flux in the solder, which in

3

Summary of Contents for T 2418

Page 1: ...tructions LED display Simple push button operation Silicone burn proof iron lead Free standing iron holder with tip cleaner Temperature adjustable Temperature correction adjustment Suitable for ROHS compliant soldering ESD safe and spike free circuitry Grounding socket ...

Page 2: ...your health do not inhale solder fumes Product Description The T 2418 digital readout electronically temperature controlled soldering station has been designed to meet the present and future soldering needs of the electronic production industry hobbyist and student The unit has a slender soldering iron pencil design with a burn proof silicone cord and a comfortable rubber grip that prevents operat...

Page 3: ...c Rubber Handle Bending T 2442B T 2434 Heater Collar Guard Complete T 2418A Handle Exploded View Diagram The handle suits tips T 2434 0 8mm conical supplied T 2435 1 6mm chisel sold separately T 2436 3 2mm chisel sold separately 6 ...

Page 4: ...cleaning wet the tip and wrap rosin core solder completely around the newly exposed surfaces GENERAL CLEANING The outer cover of the iron and station may be cleaned with a damp cloth using small amounts of liquid detergent Never submerse the unit in liquid or allow any liquid to enter the case of the station Never use any solvent to clean the case IMPORTANT SERVICE NOTE There are no user serviceab...

Page 5: ...nit reaches the display set temperature the heater indicator light Item 3 above flashes to indicate the unit has reached the set operating temperature Once operating temperature has been reached tin the surface of the tip by applying a new covering of solder to the tip Tip tinning is necessary to protect the life of the tip 4 Once the tip is tinned let the station idle for about 3 minutes then pre...

Page 6: ...ys preset correction value A Centigrade temperature correction 99 C 99 C Press 5 or 6 key to change the temperature correction amount If the temperature on the display is more than the temperature of the tip input a positive figure Eg If the current display set temperature is 200 C the actual temperature of the tip is only 190 C and the temperature offset is 00 enter 10 C If there is already a tem...

Page 7: ...lease note that the lead free solder alloys require a higher soldering temperature which shortens tip life COMMON CAUSES OF TIP UNWETTING solder not taking 1 Tip temperature higher than 410 C 770 F 2 The tip working surfaces are not well tinned while the iron is idling 3 Lack of flux in soldering wicking repairing and touch up etc operation 4 Wiping tip on a high sulphur content sponge dirty or dr...