Carefully remove any marks on the cuff with a damp cloth and mild detergent. 

Accuracy test 

We recommend this device is tested for accuracy every 2 years or after mechanical impact 

(e.g. being dropped). Please contact your local Microlife-Service to arrange the test (see 

foreword). 

 

11. Guarantee 

Limited 1 year warranty: 

Your Automatic Wrist Blood Pressure Monitor is warrantied for 1 year by the manufacturer, 

against manufacturer defects for the original purchaser only, from date of purchase. 

The 1 year warranty applies to the monitor. Batteries are not covered by this warranty. There 

are no user serviceable parts inside. The warranty does not apply to consequential and 

incidental damages, or damage caused by batteries, improper handling, and accidents. 

Professional use, not following the operating instructions, and alterations made 

to the monitor or accessory by third parties, are also not included in this warranty. Some 

states do not allow the exclusion or limitation of incidental or consequential damages, so the 

above limitation or exclusion may not apply to you. 

The manufacturer will investigate your concern. A monitor or accessory as defined by this 

warranty, determined to be out of specification, will be replaced and shipped to you at no 

cost. A monitor or accessory as defined by this warranty, determined to be within 

specification, will be returned to you with a report of findings, at no cost. 

Please call customer service: 1-888-287-1915 to obtain the address of the inspection center 

regarding any warranty concerns. We ask that you please contact customer service before 

sending any product back in order to better identify, and more quickly process, your concern. 

 

 

Summary of Contents for BP W70 BT

Page 1: ...BP3KN1 3B 1 IB BP3KN1 3B V4920 EN EN Microlife BP W70 BT BP3KN1 3B User Manual English...

Page 2: ...ch from the hand This blood pressure monitor IS NOT intended for use with Pregnancy Preeclampsia Children under 12 Neonatal patients WARNING Potentially hazardous situation that if not avoided may res...

Page 3: ...zardous situation that if not avoided may result in minor moderate injury property damage and or damage to the device This device contains sensitive electronics components Avoid strong electrical or e...

Page 4: ...against vertically falling water drops when the device is tilted up to 15 Type BF Applied Part Batteries and electronic instruments must be disposed of in accordance with the locally applicable regula...

Page 5: ...The device has been evaluated to meet general RF exposure requirement The device can be used in portable exposure condition without restriction Trademark Usage Apple the Apple logo iPad and iPhone are...

Page 6: ...monitor 4 How do I get started 4 1 Inserting the batteries 4 2 Selecting standard or MAM mode 4 3 Selecting Heart Level Indicator 4 4 Setting the date and time 4 5 Setting the user 5 How do I take a...

Page 7: ...ruction manual carefully to ensure correct use If you have additional questions regarding blood pressure measurements please contact your doctor 1 2 Inflation mode technology Please note that this dev...

Page 8: ...above 100 mmHg while at rest In this case please consult your physician immediately Long term values at this level endanger your health due to continual damage to the blood vessels in your body If you...

Page 9: ...n can be ascribed to specific organ malfunctions Please consult your physician for information about the possible origins of your own increased blood pressure values d There are measures you can take...

Page 10: ...Battery Compartment 6 Cuff 7 Systolic Value 8 Diastolic Value 9 Pulse Rate 10 Date Time 11 Stored Value 12 Traffic Light Indicator 13 Irregular Heartbeat IHB Symbol 14 Cuff Signal Indicator ERR 1 15 C...

Page 11: ...sure they are correctly connected as shown on the symbols in the compartment If the blood pressure monitor is left unused for long periods remove the batteries from the device 4 2 Selecting standard o...

Page 12: ...LED is lighted with a heart symbol Conversely 1 or 2 upward arrow s appear when your wrist height is lower to heart level and raise the wrist higher as indication Adjust your wrist to correct height l...

Page 13: ...that your wrist is free Always ensure that the cuff is positioned correctly as shown in the pictures illustrated on the short instruction card Fit the cuff comfortably but not too tight The cuff will...

Page 14: ...the ON OFF button e g if you feel uneasy or an unpleasant pressure sensation 5 4 Stopping a measurement If it is necessary to interrupt a blood pressure measurement for any reason e g the patient feel...

Page 15: ...optimal cuff fit 15 A are not considered in the average value Memory full Pay attention that the maximum memory capacity of 99 memories is not exceeded When the 99 memory is full the oldest value is a...

Page 16: ...and time must be reset the year number therefore flashes automatically after the batteries are replaced after MAM mode and Heart Level Indicator setting Which batteries and which procedure Use 2 new...

Page 17: ...minutes until a connection occurs To manually activate the Bluetooth on your monitor press and hold the power button for approximately 4 seconds or until the Bluetooth icon starts blinking If a conne...

Page 18: ...ate and no result can therefore be displayed Read through the checklist for performing reliable measurements and then repeat the measurement ERR 6 MAM Mode There were too many errors during the measur...

Page 19: ...ently fails to measure blood pressure values or the values measured are too low too high 1 Check the positioning of the cuff 2 Measure blood pressure again in peace and quiet carefully following the d...

Page 20: ...p a minimum distance of 3 3 m from such devices when using this device Do not use this device if you think it is damaged or notice anything unusual Never open this device If the device is not going to...

Page 21: ...improper handling and accidents Professional use not following the operating instructions and alterations made to the monitor or accessory by third parties are also not included in this warranty Some...

Page 22: ...pulse Cuff pressure display range 0 299 mmHg Resolution 1 mmHg Static accuracy pressure within 3 mmHg Pulse accuracy 5 of the readout value Voltage source 2 x 1 5 V alkaline batteries size AAA Battery...

Reviews: