background image

18

 

  Do not let unsupervised children use the 

monitor. Some of the components are so 
small that children can swallow them or 
choke on them. Beware of the risk of 
strangulation in case this monitor is fitted 
with cables or tubes.

Monitor care

Clean the monitor with a soft, dry cloth only.

Cleaning the cuff

Remove stains on the cuff carefully with a damp 
cloth and soapsuds or a commercial disinfectant.

  WARNING: Do not wash the cuff in a 

washing machine or a dishwasher

!

  WARNING: Do not dry the cuff in a tumble 

dryer

!

Accuracy test

We recommend having have this monitor tested for 
accuracy every 2 years or after severe mechanical 
impact (e.g. the device dropped to the floor).  
Please contact the aponorm

®

 customer service on 

the website www.aponorm.de. 

Disposal

  Batteries and electronic devices must not be 

disposed of as normal domestic trash. They 
must be disposed of in accordance with the 
applicable local provisions.

10. Warranty terms

We are confident in the quality of our aponorm

®

 

blood pressure monitors. Therefore we, WEPA 
Apothekenbedarf GmbH & Co. KG, grant end 
customers who are private consumers, a voluntary 
5 year warranty for all aponorm

®

 blood pressure 

monitors purchased in Germany, subject to the 
following terms: 
 

Subject matter and scope of the warranty

The warranty applies to all aponorm

®

 blood 

pressure monitors which customers purchased in 
Germany in their capacity as consumers. WEPA 
Apothekenbedarf GmbH & Co. KG warrants the 
customer that the product is free from defects in 
material and workmanship. Should, despite proper 
handling of the product, a defect occur within the 
5-year warranty period, WEPA Apothekenbedarf 
GmbH & Co. KG will repair the product free of 
charge (except for the transport costs for returning 
the monitor to WEPA) or fully replace it at its 
discretion. 

Exclusion of warranty 

No claims can be derived from this warranty in case 
of damage caused by the customer’s or third par-
ties’ negligence such as drop, accident or improper 
handling. The same applies to damage caused by 

Summary of Contents for Aponorm Professional Control

Page 1: ...of the most common causes of strokes user Arrhythmia detection storage slots Children Diabetics Kidney disease Also suitable for Pregnant women YEARS WARRANTY CLINICALLY VALIDATED Traffic light displa...

Page 2: ...aponorm Professional Control D E...

Page 3: ...ad the operating instructions before use Display 11 Systolic value 12 Diastolic value 13 Pulse indicator 14 MAM mode multiple measurement mode active 15 Stored value 16 Cuff check A Cuff position and...

Page 4: ...rtension diabetes for pregnant women preg nant women suffering from preeclampsia patients suffering from atherosclerosis terminal kidney diseases obesity and for the elderly The monitor can detect irr...

Page 5: ...developed and clinically tested in cooperation with internationally renowned medical specialists Atrial fibrillation is detected with a certainty of 97 to 100 1 2 If you have any questions or problem...

Page 6: ...list for taking a reliable measurement 11 4 Taking the blood pressure 12 Manual inflation 13 How not to store a reading 13 How do I evaluate my blood pressure 13 Pulse arrhythmia detector PAD 13 5 Dat...

Page 7: ...by a cardiologist based on his her interpre tation of an electrocardiogram Keep your arm still during the measurement in order to prevent incorrect results In patients with pacemakers or defibrillator...

Page 8: ...d to know whether you suffer from atrial fibrillation For more information refer to the website of the monitor manufacturer Microlife at www microlife ch afib 2 Using the monitor for the first time In...

Page 9: ...it will go Selecting multiple MAM or individual measurement Please select before each measurement whether you want to perform a normal single measurement NO MAM symbol 14 in the display or a multiple...

Page 10: ...least 5 minutes Keep your feet flat on the floor and do not cross your legs Always take your blood pressure on the same arm normally the left one It is recommended that doctors perform double arm meas...

Page 11: ...or 16 E In this case re position the cuff hold your arm still and repeat the measurement Read also chapter 8 on page 17 4 Once the correct pressure is reached the in flation stops and the pressure gra...

Page 12: ...n the optimum green increased yellow or high red blood pressure range The classification corresponds to the fol lowing ranges defined by international guidelines ESH ESC JSH values in mmHg Range Systo...

Page 13: ...ot included in the average Ensure that the maximum memory capacity of 99 values is not exceeded When the memory is full the oldest value is automatically over written with the 100th value Therefore th...

Page 14: ...batteries Only use NiMH type reusable batteries When the flat battery symbol appears remove the batteries and recharge them They must not remain in the monitor as they may become destroyed exhaustive...

Page 15: ...osed flyer 8 golden rules of taking the blood pressure For more detailed help in troubleshooting the monitor please refer to the download section of the www aponorm de product website Error Designa ti...

Page 16: ...he measurement Error Designa tion Potential cause and remedy LO Pulse too low The pulse rate is too low less than 40 beats per minute Repeat the measurement Please consult your doctor if this or any o...

Page 17: ...diagnosis It is not a substitute for a professional evaluation by a physician in parti cular not if the result does not correspond to the patient s physical condition Never rely on blood pressure meas...

Page 18: ...cal provisions 10 Warranty terms We are confident in the quality of our aponorm blood pressure monitors Therefore we WEPA Apothekenbedarf GmbH Co KG grant end customers who are private consumers a vol...

Page 19: ...ase or the warranty card filled in by the distributor directly to WEPA Apothekenbedarf GmbH Co KG or the distributor where the customer had purchased the product If the fault damage is covered by the...

Page 20: ...play range 0 299 mmHg Measuring resolution 1 mmHg Static accuracy Pressure within 3 mmHg Pulse rate accuracy 5 of the readout value Voltage source 4 x 1 5 V alkaline batteries size AA Mains adapter DC...

Page 21: ...Wepa_IB cover_BP_ ProfessionalControl_4G_1019 23...

Page 22: ...ife ch Functional overview Important advice Inthedownloadsectionof www aponorm deyoufindtheseinstructionswith updatesindigitalformfordownload alsoinGerman Turkish FrenchandRussian Homepage Cuff check...

Reviews: