MHX-2400 Operating Manual: Chapter 3 Configuration Options
S Register 120 - RTS/DCD Framing
S Register 121 - DCD Timeout
The MHX-2400 supports two special types of data framing:
•
Input (or RTS/CTS) Data Framing; and,
•
Output (or DCD) Data Framing
Input Data Framing is enabled by configuring the Handshaking Parameter as
&K2. This type of framing makes use of the S120 parameter as illustrated
in Figure 5. Parameter S120 can be set to any value between 0 and 254 ms.
RTS
CTS
TXD
S120 (ms)
Data going into MHX-910
0 to 1 ms
Figure 5 - Input Data Framing
To enable output (DCD) data framing, set the Data Carrier Detect parameter
as &C2. This type of framing uses both S120 and S121 registers as shown
in Figure 6. Valid ranges for each parameter are 0 to 254 ms.
DCD
RXD
Data leaving MHX-910
S120 (ms)
S121 (ms)
Figure 6 - Output Data Framing
S Register 123 - RSSI Reading
This register displays the average signal strength in dBm over the previous
four hop intervals. Valid RSSI readings apply only to units configured as
Slave or Repeater.
Summary of Contents for MHX-2400
Page 4: ......
Page 29: ...MHX 2400 Operating Manual Chapter 3 Configuration Options 25...
Page 31: ...MHX 2400 Operating Manual RS 232 Interface and Cables 27...
Page 32: ......
Page 34: ...30 MHX 2400 Operating Manual Appendix B Serial Interface...
Page 36: ...32 MHX 2400 Operating Manual Appendix C Sample Schematic Diagram...
Page 38: ...34 MHX 2400 Operating Manual Appendix D Factory Default Settings...
Page 40: ...36 MHX 2400 Operating Manual Appendix E Performance Tables...
Page 42: ...38 MHX 2400 Operating Manual Appendix F Hopping Patterns...
Page 44: ...40 MHX 2400 Operating Manual Appendix G Technical Specifications...