4.0 Configuration
4.0 Web User Interface
Initial configuration of an BulletPlus using the Web User (Browser) Interface (Web UI) method involves the
following steps:
configure a static IP Address on your PC to match the default subnet
or
if your PC is configured for
DHCP, simply connect a PC to a LAN port of the BulletPlus and it will be assigned a IP address
automatically.
connect the BulletPlus ETHERNET(LAN) port to PC NIC card using an Ethernet cable
apply power to the BulletPlus and wait approximately 60 seconds for the system to load
open a web browser and enter the factory default IP address(192.168.168.1) of the unit:
logon window appears; log on using default Username:
admin
Password:
admin
use the web browser based user interface to configure the BulletPlus as required.
refer to
Section 2.0: Quick Start
for step by step instructions.
In this section, all aspects of the Web Browser Interface, presented menus, and available configuration
options will be discussed.
Image 4-0-1: WebUI
The factory default network
settings:
IP: 192.168.168.1
Subnet: 255.255.255.0
Gateway: 192.168.168.1