background image

14 

 

11. MAINTENANCE AND CLEANING 

 

The following points have to be considered during the inspection: 
 
1)  All screws for installing the device, or parts of the device must be tightly connected, and must not be corroded. 
 
2)  There must not be any deformations on the housing, colour lenses, fixations or installation spots (ceiling, suspension, 
trussing). 
 
3

Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances. 

 
4

The electric power supply cables must not show any damage, material fatigue or sediments.  

Further instructions depending on the installation spot and usage must be handled by a skilled installer or technician. Any 
safety issues must be resolved. 
 
 

 

 
 
In order to keep the fixture in good condition and extend the life, we suggest regular cleaning to the fixture. 
 

1)  Clean the inside and outside lens each week to avoid the light output from darkening due to accumulation of dust, 
dirt, etc. 

 

2)  Clean the fan each week. 

 

3)   A detailed electrical check by approved technician every three months is advised. Ensure the circuit contacts are 
in good condition, and prevent from overheating.  

 
 
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use alcohol or solvents. 
There are no serviceable parts inside the device. Please refer to the instructions under “Installation instructions”. 
Should you need any spare parts, please order genuine MICROH parts from your local dealer. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

IF YOU SHOULD EXPERIENCE ANY PROBLEMS OR ISSUES PLEASE CONTACT MICROH PROFESSIONAL 
PRODUCTS BY EMAIL AT 

[email protected]

  

 

In the event that your unit is defective in any way, please contact your local dealer to obtain an RA number for 
service repair.  
 

DISCLAIMER – MICROH believes that the information contained within this user manual is accurate. However, 
Microh is not responsible for any error or addendums to this manual. If you have any comments or general 
suggestions on how this manual can be improved please contact 

[email protected]

. Thank you 

Summary of Contents for LED Razor45

Page 1: ......

Page 2: ...ash is made of a new type of high temperature strength of engineering plastics and cast aluminum The fixture is designed and manufactured strictly following CE standards complying with international s...

Page 3: ...d on or near combustible substances Keep more than 50cm distance from wall for proper ventilation and air flow If your fixture is or has become damaged in any way it shall be exclusively replaced or r...

Page 4: ...f DMX channels and allows one to control multiple units independently or simultaneously on a small DMX console The figure below shows a simple DMX layout On the same starting channel say 001 there are...

Page 5: ...it in PROGRAM Auto and Sound mode to run the whole system In Master Slave operating mode all Slave units are to be set to Slave Mode and Slave ID is required for each Slave unit 1 Press MENU button go...

Page 6: ...press Fun button to enter Test Mode 2 Use Up Down button to select Test LED or Test Fan then press Fun button to go to Test LED or Test Fan 3 Press Up Down to test Red Green Blue White and Amber LEDs...

Page 7: ...onnectors Please refer to the diagram below DMX 512 Connection With DMX Terminator For installations where the DMX cable has to run a long distance or is in an electrically noisy environment it is rec...

Page 8: ...7 6 MENU NAVIGATION When navigating the menu Use UP button to move up Use DOWN button to move down Use FUN button to move right Use MENU button to move left...

Page 9: ...150 Colour 29 151 156 Colour 30 157 161 Colour 31 162 166 Colour 32 167 171 Colour 33 172 176 Colour 34 177 182 Colour 35 183 187 Colour 36 188 192 Colour 37 193 197 Colour 38 198 202 Colour 39 203 20...

Page 10: ...Brightness Adjust 0 100 6 Blue 000 255 Brightness Adjust 0 100 7 White 000 255 Brightness Adjust 0 100 8 Amber 000 255 Brightness Adjust 0 100 Section 2 9 Strobe 000 004 No Function 005 255 Strobe Sl...

Page 11: ...ds to Center 4 LED 1 Red 000 255 Brightness Adjust 0 100 5 LED 2 Green 000 255 Brightness Adjust 0 100 6 LED 3 Blue 000 255 Brightness Adjust 0 100 7 LED 4 White 000 255 Brightness Adjust 0 100 8 LED...

Page 12: ...000 255 Brightness Adjust 0 100 10 LED 6 Red 000 255 Brightness Adjust 0 100 11 LED 7 Green 000 255 Brightness Adjust 0 100 12 LED 8 Blue 000 255 Brightness Adjust 0 100 13 LED 9 White 000 255 Bright...

Page 13: ...ace lens kit and follow reverse steps to close the fixture IMPORTANT When replacing the lens assembly please make sure that the power is disconnected from the fixture beforehand LEDs on PCBs are sensi...

Page 14: ...13 10 UNIT OVERVIEW...

Page 15: ...accumulation of dust dirt etc 2 Clean the fan each week 3 A detailed electrical check by approved technician every three months is advised Ensure the circuit contacts are in good condition and preven...

Page 16: ......

Reviews: