11 of 11
RX10 Ten-Zone Receiver Decoder
c) Options
i) Reset
A specific RIC + beep type can be used to reset the RX10 over the air. The Enable tick box must be checked.
ii) Common Relay/Sounder
When any relay zone is activated, the common relay will be triggered. This can be programmed to stay
latched by checking the “Fixed” option, or it can be programmed for momentary activation by checking the
“Timed” option and entering the duration required (maximum is 255 seconds). The sounder can be
programmed to activate when the common relay is triggered by checking the “Link Common
relay/Sounder” box.
iii) Repeated Toggle Command Filter
Where the transmitter is programmed to send repeat calls for added integrity, it may be required to filter
out these repeats if the “Toggle” function is being used (otherwise the relay will change state every time a
repeat call is received). Enter the required time in the box provided (1-255 seconds). Note that this is not
necessary where only the “Close” or “Open” functions are being used, as these will ignore repeats of the
same RIC.