background image

Micro

Dome

® 

Duo

 

Installation

 Manual 

 

 
Models: 

 

  4 Megapixel 

  AV4655DN-08 
  AV4655DN-28 
  AV4655DN-NL 
 

4 Megapixel WDR

 

AV4656 DN-08 
AV4656DN -28 
AV4656DN-NL 

 

 

 
   6 Megapixel 

       AV6655DN-08 
       AV6655DN-28 
       AV6655DN-NL 
 

   6 Megapixel WDR 

     AV6656DN-08 
     AV6656DN-28 
     AV6656DN-NL 

 

 
10 Megapixel 

      AV10655DN-08 
      AV10655DN-28 
      AV10655DN-NL 
 

 

 

 

 

 

 

 

 

Summary of Contents for AV10655DN-08

Page 1: ...pixel AV4655DN 08 AV4655DN 28 AV4655DN NL 4 Megapixel WDR AV4656 DN 08 AV4656DN 28 AV4656DN NL 6 Megapixel AV6655DN 08 AV6655DN 28 AV6655DN NL 6 Megapixel WDR AV6656DN 08 AV6656DN 28 AV6656DN NL 10 Me...

Page 2: ...Installation 10 MDD FMA Flush Mount Installation 11 Pan and Tilt Adjustment 14 Lens Replacement 15 Usage of Ethernet cable other than included M F PoE cable 16 Connecting Digital I O 17 AUX I O use ca...

Page 3: ...cure mount Package Content This equipment should be unpacked and handled with care The original packaging is the safest container in which to transport the unit and can be used if returning the unit f...

Page 4: ...ted to unusual stress neglect misuse abuse improper storage testing or connection or unauthorized repair or iv is no longer covered under the Warranty Period ARECONT VISION MAKE NO WARRANTIES OR CONDI...

Page 5: ...quality at any time of day For applications with bright or over saturated lighting conditions optional wide dynamic range delivers up to 100dB at full resolution and is available on select 4 and 6MP...

Page 6: ...4 screws which secure the cover PIC 1 3 Remove the cover Do not remove screws from the dome cover 4 Use Phillips screwdriver to loosen the four 4 screws securing the camera to adapter plate PIC 2 som...

Page 7: ...ual Page 7 support arecontvision com 1 818 937 0700 877 CAMERA 8 www arecontvision com avsales arecontvision com PIC 3 PIC 4 8 Re attach camera to adapter plate Reverse step 4 and 5 9 Re attach cover...

Page 8: ...ll bits for four mounting holes in Drop Ceiling Panel 7 Using enclosed 6 32 screws attach enclosed Drop Ceiling Mount Plate Adapter and Adapter Plate onto opposite sides of Drop Ceiling Panel so the p...

Page 9: ...com MDD CAP Installation Repeat step 1 5 of Surface Installation See Pic 1 3 6 Insert Adapter Plate into the Cap and attach it to the cap using the 4 screws through 4 A holes using enclosed 6 32 scre...

Page 10: ...1 818 937 0700 877 CAMERA 8 www arecontvision com avsales arecontvision com MDD CMT WMT Pendant Mount and Wall Mount Installation Assembly Pic 7 can be used with wall mount or ceiling mount PIC 8 PIC...

Page 11: ...igned for indoor use only Grommet use is recommended 1 Use template to cut the ceiling plate and create mounting provisions for the Flush Mount Ceiling Panel PIC 10 2 Use the supplied security L key t...

Page 12: ...upport arecontvision com 1 818 937 0700 877 CAMERA 8 www arecontvision com avsales arecontvision com 4 Plug PoE cable not shown for clarity 5 Hold all four latches as shown on PIC 12 PIC 12 6 Insert c...

Page 13: ...37 0700 877 CAMERA 8 www arecontvision com avsales arecontvision com PIC 14 7 Undo 4 screws shown and remove both Rings and Bubbles PIC 15 Bubbles Rings 8 Adjust Pan and Tilt for both modules as shown...

Page 14: ...re the cover See Pic 1 2 Remove the cover 3 Adjust the pan and tilt of each camera module to obtain the desired field of view Do not to press the remote focus motor against the sides of camera module...

Page 15: ...Lens Replacement 1 Use the supplied security L key to loosen the four 4 screws which secure the cover See Pic 1 Remove the cover PIC 18 2 Manually turn the lens counter clockwise this may take several...

Page 16: ...to Grommet Installation Tool as shown on Pic 19 2 If intend to use AC DC power to power up the camera insert the wire not supplied into grommet See instructions on page 23 for cable preparation 3 If i...

Page 17: ...stics MIN MAX PIN I O CABLE WIRE COLOR Input Voltage V Measured between and terminals ON 2 9 6 3 3 WHITE OUT OFF 0 1 3 4 BLACK OUT Output Current mA Measured between and terminals Applied Voltage Rang...

Page 18: ...ion com 1 818 937 0700 877 CAMERA 8 www arecontvision com avsales arecontvision com AUX I O use case example Arecont Vision AUX I O ALARM IN S D G ALARM OUT ALARM OUT 120V 100mA max Normally Open Clos...

Page 19: ...ate the relay during an active connection using the API command set Typical applications include turning on lights or activating doors and locks IN IN GND OUT OUT 0 120VDC 100mA max Relay wiring with...

Page 20: ...eme the IN IN terminals can be used for external signaling devices such as door contacts or motion detectors Both normally open and normally closed devices are supported as shown below IN IN GND OUT O...

Page 21: ...amera can detect a range of voltage to trigger an internal alarm on off condition IN IN GND OUT OUT 0 12VDC 50mA max The following table shows the input voltage range and electrical characteristics In...

Page 22: ...of the local government where the camera is installed and no bare wires are exposed 1 Remove cover from the camera as described on page 6 2 Plug one end of Ethernet cable into female end of pre instal...

Page 23: ...er cable to the 4 position connector on the Main Board see Page 17 and 18 for illustration and detailed instructions 2 The Poke Home connector requires 18 AWG to 24 AWG wire solid or stranded 3 Please...

Page 24: ...uding broadcast and multicast check the status of a camera change camera settings import and export camera settings via a csv file and update firmware and or hardware from virtually anywhere with a ne...

Page 25: ...o it with a web browser and a GUI interface DHCP The Dynamic Host Configuration Protocol allows network administrators to centrally manage and automate the assignment of IP addresses DHCP should only...

Page 26: ...ebpage the recommended browsers are Internet Explorer and Firefox Figure 1 Double click via AV IP Utility Figure 2 Type the camera IP address 2 Scroll to the Focus Tab section NOTE Additional informat...

Page 27: ...Duo Installation Manual Page 27 support arecontvision com 1 818 937 0700 877 CAMERA 8 www arecontvision com avsales arecontvision com 5 Please complete the same action for Channel 2 by following step...

Page 28: ...ally scans the full focus range of the scene to find the best focus position Short range Focus Best for scenes that are slightly of out of focus The camera quickly fine tunes for a precise focus posit...

Page 29: ...no password protection and allows full anonymous access from the network In case the admin password has not been set the camera has full anonymous access from the network even if the viewer password h...

Page 30: ...h position on board The camera has been reset to the factory default If the camera is not connected to DHCP server the camera will use Link local address The Reset to Factory Default can be done via c...

Page 31: ...31 support arecontvision com 1 818 937 0700 877 CAMERA 8 www arecontvision com avsales arecontvision com Troubleshooting Before troubleshooting visit http www arecontvision com to ensure your camera...

Page 32: ...to factory default with AV200 or the camera webpage Upgrade to the latest firmware by visiting ArecontVision com Isolate the camera on a dedicated network and test with AV200 Swap the troubled camera...

Reviews: