Printer Commands
Chapter 5
))))))))))))))))))))))))))))))))))))))))))))
))))))))))))))))))))))))))))))))))))))))))))
32
410 ECA Operators Manual
^A
^D
COMMAND
22
Change SW2:
Software dip switch #2. Below is the ^AB sequence:
12345678
^ABxxxxxxxx
*******.)))),
******.)))),*
*****.)))),**
*****
RRR
Power-up Tag Format
*****
000=ALWAYS EPROM Format 1
*****
001=ROM or Saved Format File 1
*****
010=ROM or Saved Format File 2
*****
011=ROM or Saved Format File 3
*****
100=ROM or Saved Format File 4
*****
101=ROM or Saved Format File 5
*****
110=ROM or Saved Format File 6
*****
111=ROM or Saved Format File 7
****.))))Q
1=Use Saved Format File, 0=Rom Format
***.)))))Q
1=Print Button Enable, 0=Disable
**.))))))Q
1=Disable Button Use, 0=Enable
*.)))))))Q
1=>RESTARTED< Response Enable, 0=Disable
.))))))))Q
1=Clear Text Enable, 0=Disable
Position:
1
Clear Text Function:
If enabled, all variable text strings will be erased when a
^D2
5
is processed.
2
>RESTARTED< Response:
If the printer has been reset and this switch has been
enabled, the printer will respond with to the first poll by sending the
>RESTARTED< message. If additional enquiries are made the printer will respond
normally. The >RESTARTED< message is only sent once after reset.
3
Button Use:
Set to 1, the printer will not allow button use, even for paper feed.
4
Print Button:
If this is 0, the button can be used for paper feed, but cannot be
used to initiate tag printing.
5
Power-up Format Type:
Defines the power-up tag format. This parameter
determines whether to use a saved format file for the power-up tag, or a ROM
format (defined by positions 6, 7, and 8). The saved format file must be battery
backed to use the saved format file feature. See Appendix C for configuration
instructions and section 5.3.7 for saved format file information. Please consult your
service organization if changes or additions to the fixed ROM formats are required.
6,7,8
Power-up Tag Format:
These switches decide which format to use at power-up.