background image

RA

VEN 440/450 C

ONNEC

TION

P/N 17601

(15 FE

ET

)

GROUND

POWER

SEE 
TA

BLE

FOR OPTIONA

L

EXTENSION CABLES

P/N 17359

P/N 17358

(20 FEE

T)

SEC

TION 

BY

PASS 

VA

LV

E

RP

M

CONTROL 

VA

LV

E

RUN/HOLD w/DUST 

CO

VER

BROWN 

TIES

GR

AY

 TIE

BROWN 

TIE

20

5’

20

Instructions for Micro-Trak

Seed Rate Control Systems

Used with Raven Controllers

440/450 - Single Section

P/N 50289 Rev A • © 2009 • Page 1

1.  Install  system  components  and  harnessing  per  general             

instruction manual (Micro-Trak P/N 17632).

2.  See attached system and wiring diagrams for Raven 

440/450-specific harnessing.  Note the different diagrams for 

single drive or multi-drive systems.

3.  See page 10 for Calculating Flow Cal or Pulses per 1000 Seeds 

to be entered in the 440/450 Application Rate Controller Pro-

gram.

Single Drive Harness Kit System Diagram

OPTIONAL 10-PIN CABLES

P/N 13220

5'

CABLE

P/N 13221

10'

CABLE

P/N 13222

15'

CABLE

P/N 13223

20'

CABLE

P/N 13224

25'

CABLE

P/N 14142

50'

CABLE

OPTIONAL 5-PIN CABLES

P/N 14482

5'

CABLE

P/N 14483

10'

CABLE

P/N 14484

15'

CABLE

P/N 14485

20'

CABLE

P/N 14486

25'

CABLE

Summary of Contents for 17632

Page 1: ...nessing per general instruction manual Micro Trak P N 17632 2 See attached system and wiring diagrams for Raven 440 450 specific harnessing Note the different diagrams for single drive or multi drive...

Page 2: ...20 GA BLU 20 GA VIO 20 GA GRY 20 GA WHT 20 GA BLK A B C D E F G H J K 10 PIN M P SHROUD 18 GA RED 18 GA BLK P N 17358 5 PIN M P SHROUD A B C D E A B C D E F G H J K 10 PIN M P TOWER 18 GA RED 18 GA WH...

Page 3: ...OL SYSTEM THREE SECTION DIAGRAM RED TIE 120 BROWN TIE 240 BROWN TIES 240 RED TIES 120 ORANGE TIES 240 GRAY TIE 60 240 CONNECT TO RAVEN 440 450 P N 17582 w o POWER 120 IN POWER GROUND P N 50289 Rev A 2...

Page 4: ...GA BLK A B A B A B 2 PIN M P TOWER 2 PIN M P TOWER 2 PIN M P TOWER 12V GND 12V GND 12V GND DUST COVER SECTION 1 BYPASS VALVE SECTION 2 BYPASS VALVE SECTION 3 BYPASS VALVE ORANGETIE 10 PIN M P TOWER A...

Page 5: ...SEED RATE CONTROL SYSTEM FIVE SECTION DIAGRAM RED TIE 120 BROWN TIE 240 BROWN TIES 240 RED TIES 120 ORANGE TIES 240 GRAY TIE 60 240 YELLOW TIES 240 YELLOW TIE 240 GREEN TIES 120 GREEN TIE 120 RAVEN 44...

Page 6: ...M GROUND CONTROL VALVE CONTROL VALVE RUN HOLD SIGNAL RUN HOLD POWER RUN HOLD GROUND SECTION 4 BYPASS VALVE SECTION 5 BYPASS VALVE SIGNAL POWER SECTION 5 RPM GROUND SIGNAL POWER SECTION 4 RPM GROUND 2...

Page 7: ...rollers Single Drive Open Center Diagram RETURN PRESSURE HYDRAULIC FLOW CONTROL VALVE CHECK VALVE RPM SENSOR SECTION BYPASS VALVE RETURN PRESSURE SECTION BYPASS VALVE HYDRAULIC FLOW CONTROL VALVE RPM...

Page 8: ...am RETURN PRESSURE LEFT BYPASS VALVE RIGHT RPM SENSOR RIGHT BYPASS VALVE HYDRAULIC FLOW CONTROL VALVE LEFT RPM SENSOR CHECK VALVE RETURN PRESSURE LEFT BYPASS VALVE RIGHT RPM SENSOR RIGHT BYPASS VALVE...

Page 9: ...IGHT RPM SENSOR RIGHT BYPASS VALVE HYDRAULIC FLOW CONTROL VALVE LEFT RPM SENSOR CHECK VALVE CENTER BYPASS VALVE CENTER RPM SENSOR RETURN PRESSURE LEFT BYPASS VALVE RIGHT RPM SENSOR RIGHT BYPASS VALVE...

Page 10: ...ket x Second Stage Driven Sprocket Second Stage Drive Sprocket x Third Stage Driven Sprocket Third Stage Drive Sprocket EXAMPLE 32 16 x 28 16 x 24 18 4 666 In the above example the First Stage Drive S...

Page 11: ...cket varies by planter manufacturer and model so you will need to measure to determine the length Cut to length and install using the supplied connector link 0 6 2 7 Loosen the four 3 8 flange bolts i...

Page 12: ...hes traveled per hour Inches traveled per hour DSS Seeds per hour 316800 6 5 48738 46 seeds per hour Seeds per hour SMD Seed meter revolutions per hour 48738 46 30 1624 6 seed meter revolutions per ho...

Reviews: