57
Hot
(Red)
Ground
(Black)
40 - Amp in-line
fuse required
40 Amp Standard Electric Motor Driver
Electric Motor Driver (EMD) Module
40 A
MP
M
AXIMUM
The Electric Motor Driver Module (EMD) replaces the servo
valve. System flow is controlled by regulating the pump
speed.
IMPORTANT!
The EMD
MUST
be connected to a 12-volt DC
negative ground electrical system.
IMPORTANT!
Route all cables away from sharp edges, areas
of high heat and moving parts. Secure them firmly with
plastic cable ties.
INSTALLATION STEPS
1. Install Module
Remove the backing from the Dual-Lock TM fasteners and
attach to the bottom of the EMD unit. Position the EMD
where wiring will work the best. Extension cables are
available. Firmly press the EMD into place. Secure the EMD
to the equipment using plastic cable ties to prevent the EMD
from coming into contact with moving parts if the Dual-Lock
TM fasteners should work loose. If desired, the EMD can
be fastened with screws, using the holes in the mounting
flanges.
NOTE: The mounting surface must be free from dirt,
moisture and oil residues. Failure to clean the mounting
surface may result in the EMD working loose.
2. Connect Battery Power to Module
•
Locate the power cable, P/N 18419 and route cable to
the battery. Connect BLACK wire to ground. Connect
RED wire to positive battery terminal. Be sure there is a
good metal-to-metal contact.
•
Connect the power to the EMD by plugging the 2-pin
M/P tower on the power cable into the 2-pin M/P shroud
of the EMD module.
3. Connect Module to Controller
IMPORTANT!
Micro-Trak Controller MUST be set to “BYPASS” .
•
Locate the boom wire, P/N 17279. Plug the 2-pin
W/P shroud into the mating connector on the EMD
module and plug the 3-pin W/P shroud into the Boom
1 connector on the controller harness. If necessary,
remove the 3-pin W/P shroud and crimp P/N 10657 red
quick-disconnect terminal into end of wire.
•
Connect the servo or control input to the 3-pin 2-wire
W/P tower on the EMD module.
•
Locate the motor cable P/N 18420. Plug the 2-pin M/P
480 shroud into the 2-pin M/P 480 tower EMD module.
Connect the other end to the pump. Ensure that the
pump is running in the correct direction. If not, simply
reverse the wires from the pump to the pump cable.
Note: The +12 VDC signal is required to turn the EMD on.
Copyright © 2016
•
P/N 50361
•
041216
•
Page 1
Appendix G
Summary of Contents for 14869
Page 1: ...1 SprayMate II AUTOMATIC RATE CONTROLLER REFERENCE M A N U A L TM 1 1 1 1 1 1 1 1 1 1 1 1 1...
Page 7: ...7 SprayMateTM II System Overview P N 21778 P N 21963...
Page 8: ...8 P N 21963 P N 21779 P N 14313 P N 14316 SprayMateTM II Wiring Diagram...
Page 37: ...37 Appendices...
Page 45: ...45 P N 21779 P N 21778 Appendix F SprayMateTM II NH3 Specific Wiring Harness Diagram...