FAQ

 

 

Q: How do I know if my device is working properly?

 

 

First, plug in your coils and make sure they are plugged in all the way. Then insert a fresh, fully charged 9-volt battery. Then 
move the cycle profile switch to either position 1, 2 or 3. You should see the center yellow LED flash three times, and then see 
the upper green LED flash as the device operates. Finally, put each coil close to your ear and listen for its "click-click -click" 
sound. If you see the green LED flashing and if you hear the clicking sound, then the Alleva-Wave system is functioning 
properly.

 

 

Q: How will I know when the battery needs charging?

 

 

The LED's will become dim or will go out entirely, and you will no longer be able to hear the coils clicking. Refer to the 
"Expected Battery Life" section in this manual to determine the approximate battery life that applies to your battery 
and usage.

 

 

Q: Can I use any battery charger to recharge the battery or must I use the one supplied?

 

 

Any commercial battery charger will work as long as you have rechargeable batteries. Be sure to match rechargeable batteries 
to the correct type of charger or you could easily damage or destroy your batteries and charger. Almost all types of 
rechargeable batteries require a different specific charger: NiCad, NiMH, Li-Ion, Li-Polymer, Hybrid, etc.

 

 

Q: The device makes a clicking or humming noise. Is this normal?

 

 

Yes, this is normal. The device is humming for the same reason that power transformers on telephone poles sometimes hum 
and vibrate. The phenomenon is known as magnetostriction, and it is normal and harmless. Unfortunately it is an 
unavoidable side effect of the physical operation of the device. We are working to reduce the noise in future designs but this 
may not be possible due to the physics of the device operation. When you hear these sounds in most cases it means the 
device is operating properly.

 

 

Q:

 

One of the coils does not seem to be working (no clicking sound) but the other one still works. Will 
the device still be effective?  

 

The device will not be as effective with a non-functional coil. Both coils are required for effective stimulation and we 

recommend that you order replacement coils.

 

 

Q:

 

I would like to locate the pulse generator farther from the coils when I use the device. Are longer coil 
cables available? Or can I add an extension cable to the coil cable?  

 

We offer only one length of coil cable. We do this because the cable length of the Alleva-Wave is designed to transmit 
maximum energy to the coils. Longer cable lengths decrease the transmitted energy due to electrical losses in the cable.

 

 

If you feel it necessary to add an extension cable, it should conform to the following guidelines:

 

a)

 

cable length: 24 inches (600 mm) or shorter; shorter is better  

b)

 

cable type: high-performance audio cable; higher quality cable provides better performance  

 

c)

 

connector style: 3-conductor audio, 1/8" diameter audio plug and socket  

d)

 

connector material: gold-plated; wipe contacts clean before first use  

 

Depending on various factors, adding an extension cable will create an approximate 20% reduction in magnetic energy at 
the coils. This will reduce stimulation to the tissue and will reduce the device's effectiveness.

 

 

Q: If the pulse generator is damaged in any way, is there a chance the device can cause a fire?

 

 

NEVER use a damaged device.

 

 

Although the risk of creating fire with the device is very remote, we recommend that you do not take any risks. The units are 
internally sealed against moisture and tampering, so it is not possible to repair a pulse generator once it has sustained 
damage. We recommend you contact your distributor or supplier to order a replacement unit.

 

 

Q: I dropped the pulse generator in water. What do I need to do? Will it ever work again?

 

 

There is no guarantee it will work again. However, in some cases, if it is dried quickly and thoroughly enough, it might function 
again. First, IMMEDIATELY get the pulse generator out of the water and disconnect the battery. Then disconnect the coils. 
Second, shake the device vigorously to remove any excess water and wipe the exterior dry. Third, put about 0.5 inch (12 mm) 
of dry white rice in the bottom of a jar or bowl and place the pulse generator on top of the rice. Fourth, seal the top of the jar 
or bowl, and let sit overnight. The dry rice will absorb moisture in the container, including (hopefully) the water in the pulse 
generator. Discard the rice after use. If available, it is preferable to use desiccant instead since it will absorb moisture better 
than rice. DO NOT place the pulse generator in an oven or microwave to dry.

 

 

www.allevawave.com

 

11 of 12

 

P2 User Instruction Manual

 

Summary of Contents for Alleva-Wave P2

Page 1: ...nformation 2 Warnings and Precautions 2 Purpose of the Alleva Wave P2 System 2 Description of the Alleva Wave P2 System 3 Environmental Conditions that Affect Use 4 System Setup 5 Operating Instructio...

Page 2: ...s If you feel pain during the use of the device you should stop using it and consult your physician If you experience increased pain or discomfort you should consider using a lower power setting if av...

Page 3: ...Mode during operation 3 2 Center yellow LED Indicates the system is running power up diagnostics before operation or is in Rest Mode during operation 2 Lower red LED Indicates there is a problem with...

Page 4: ...ile switch The Alleva Wave P2 operates on a 41 minute cycle that repeats continuously and automatically Using the cycle profile switch you can select from among four predefined cycle profiles Switch M...

Page 5: ...Insert a fully charged battery into the pulse generator Confirm that its terminals are correctly aligned to the positive and negative markings on the pulse generator A rechargeable NiMH battery will...

Page 6: ...thick parts of the body when the injury is relatively close to the surface within 1 to 2 inches 25 to 50 mm of the skin In these cases the coils are situated on the same side of the injury area adjac...

Page 7: ...ght later decide to place them obliquely at an angle To the extent possible it is best to try several options to determine what seems to work best The preferred placement of the coils might ultimately...

Page 8: ...e In both cases your body experiences longer term health gains as it s subjected to a variety of different external stimulations Another reason to change coil locations is the effect of accommodation...

Page 9: ...n their flat geometry However you are encouraged to flex and conform the coils to your body contours for both comfort and greater stimulation effectiveness Neck Shoulder Elbow Lower back www allevawav...

Page 10: ...ir daily routine and their response to the stimulation You are encouraged to experiment with usage patterns and coil locations to find what works best for you Also keeping a daily written record of yo...

Page 11: ...arther from the coils when I use the device Are longer coil cables available Or can I add an extension cable to the coil cable We offer only one length of coil cable We do this because the cable lengt...

Page 12: ...d I expect a reduction in pain Each person s response to the PEMF stimulation is different and we cannot guarantee results However pain reduction often occurs within the first 3 to 4 days of use and p...

Reviews: