Page 7
surfaceCONTROL 3D 3500
The outputs can optionally be assigned the internal signals below:
Internal signal
Description
UserOutput0
Digital output signal that can be set via Genicam
FrameTriggerWait
Sensor is ready for next measurement
FrameTriggerMissed
(External) trigger was missed
(sensor was not yet ready for measurement)
FrameActive
3D measurement in sensor is active (start at exposure of first
image, end at completion of data transmission via GigE)
ExposureActive
Image sequence recording is enabled for current frame
(start at first image, end at last image transmission)
HardwareError
Critical error in sensor: Hardware error or sensor has be-
come too hot.
Fig. 6 Internal signal for digital output
Output signal selection
(software side)
(Output) Line 1
Trigger/GPIO1
(Output) Line 2
GPIO2
(Output) Line 3
GPIO3
(Output) Line 4
GPIO4
FrameTriggerWait
FrameTriggerMissed
ExposureActive
FrameActive
HardwareError
UserOutput0