background image

Page 2

surfaceCONTROL 3D 35xx

3. 

Proper Environment

 - Protection class 

 

ƒ

Sensor: 

IP67 (only applies in the case of connected output connectors  

 

and/or installed protective caps)

Optical paths during operation are excluded from the protection class.  
Contamination of the paths causes impairment or failure of the function.
The IP67 protection class is a specification that is limited to protection from dust and 
water. Oil, steam and emulsion effects are not included in this protection class and 
must be evaluated separately.

 - Temperature range  

 

ƒ

Operation: 

0 ... +45 °C

 

1

 (+32 ... +113 °F) 

 

ƒ

Storage: 

-20 ... +70 °C (-4 ... +158 °F)

 - Humidity: 

20 ... 80 % (non condensing)

 - Ambient pressure: Atmospheric pressure

1) Max. permissible operating temperature depends on installation scenario, thermal 
connection and operating mode. If necessary, external heat dissipation must be used to 
ensure that the sensor’s internal temperature of 60 °C is not exceeded.

4. 

Delivery surfaceCONTROL 3D 35xx

 - 1 Sensor surfaceCONTROL 3D 35xx
 - 1 Assembly instructions
 - 1 Calibration final inspection
 - 3 Protective caps
 - 1 ECR3000-5 supply cable 5 m
 - 1 SCR3000X-5 Ethernet interface cable 5 m

  Carefully remove the components of the measuring system from the packaging 

and ensure that the goods are forwarded in such a way that no damage can occur.

  Check the delivery for completeness and shipping damage immediately after 

unpacking.

  If there is damage or parts are missing, immediately contact the manufacturer or 

supplier.

Summary of Contents for surfaceCONTROL 3D 35 Series

Page 1: ...ly be opened by authorized persons Damage to or destruction of the sensor Do not touch the protective windows of the optics Wipe off any fingerprints immediately with pure alcohol and a clean cotton c...

Page 2: ...Ambient pressure Atmospheric pressure 1 Max permissible operating temperature depends on installation scenario thermal connection and operating mode If necessary external heat dissipation must be use...

Page 3: ...included in risk group 2 according to EN 62471 2008 Do not look into the lens Consciously close your eyes or immedi ately turn away if the optical radiation enters the eye The warning sign below is at...

Page 4: ...to 2 A per pin Designation Pin no Cable color ECR3000 x Notes Connection view U B 1 Brown 18 V 30 V DC rated value 24 V 1 2 4 3 View Plug on housing side U B 2 White GND 3 Blue 0 V GND 4 Black Screen...

Page 5: ...White reserved 1 Brown reserved 12 Red blue reserved 11 Gray pink reserved 10 Purple GPIO1 4 Green General purpose IO 1 hardware trigger GPIO2 6 Yellow General purpose IO 2 GPIO3 8 Gray General purpos...

Page 6: ...ger to start a measurement and is directly connected to the sequence control in the sensor The functionality of the digital signals can be programmed see Fig 5 In addition to direction polarity can al...

Page 7: ...sensor is active start at exposure of first image end at completion of data transmission via GigE ExposureActive Image sequence recording is enabled for current frame start at first image end at last...

Page 8: ...RV Customer Device Sensor All inputs can be used as logical inputs but not for time critical tasks Electrical Parameters of Digital Outputs Multi Function Connection The digital outputs require an ext...

Page 9: ...Communication with sensor possible Constant red Error during initialization No communication with sensor possible LED Power Meaning Off No operating voltage or operating voltage too low Constant gree...

Page 10: ...itializa tion After completion it is constantly illuminated green For more information see the LED Displays section see Chap 7 i The surfaceCONTROL 3D 35xx sensor requires a warm up time of typically...

Page 11: ...y surfaces reflections from the test object can be reduced by inclining the sensor by up to 30 with respect to the surface of the test object Alignment with Crosshair You will achieve the best results...

Page 12: ...aused by improper handling the use of force or by repairs or modifications by third parties is not covered by the liability for material defects Repairs are carried out exclu sively by MICRO EPSILON F...

Reviews: