background image

Page 4

surfaceCONTROL 3D 35xx

6. 

Electrical Connections

Fig. 2 Arrangement of connections

Power

Supply voltage

Data

Gigabit Ethernet connection

I/O

Multi-function connection

Supply Voltage (Power)

The power supply connection in the form of a 4-pin M12 round connector has a current 
carrying capacity of up to 2 A per pin.

Designation

Pin no.

Cable color 
ECR3000-x

Notes

Connection view

+

U

 B

1

Brown

18 V ... 30 V DC  
(rated value 24 V)

1

2

4

3

View: Plug on 

housing side

+

U

 B

2

White

GND

3

Blue

0 V

GND

4

Black

Screen

Housing

Fig. 3 Pin assignment of the power supply connection 

The operating voltage is protected against polarity reversal. Use only shielded lines or 
original cables from the accessories program for the power supply connection or the 
outputs. 
Micro-Epsilon recommends the ECR3000-

x

 shielded supply cable.

Summary of Contents for surfaceCONTROL 3D 35 Series

Page 1: ...ly be opened by authorized persons Damage to or destruction of the sensor Do not touch the protective windows of the optics Wipe off any fingerprints immediately with pure alcohol and a clean cotton c...

Page 2: ...Ambient pressure Atmospheric pressure 1 Max permissible operating temperature depends on installation scenario thermal connection and operating mode If necessary external heat dissipation must be use...

Page 3: ...included in risk group 2 according to EN 62471 2008 Do not look into the lens Consciously close your eyes or immedi ately turn away if the optical radiation enters the eye The warning sign below is at...

Page 4: ...to 2 A per pin Designation Pin no Cable color ECR3000 x Notes Connection view U B 1 Brown 18 V 30 V DC rated value 24 V 1 2 4 3 View Plug on housing side U B 2 White GND 3 Blue 0 V GND 4 Black Screen...

Page 5: ...White reserved 1 Brown reserved 12 Red blue reserved 11 Gray pink reserved 10 Purple GPIO1 4 Green General purpose IO 1 hardware trigger GPIO2 6 Yellow General purpose IO 2 GPIO3 8 Gray General purpos...

Page 6: ...ger to start a measurement and is directly connected to the sequence control in the sensor The functionality of the digital signals can be programmed see Fig 5 In addition to direction polarity can al...

Page 7: ...sensor is active start at exposure of first image end at completion of data transmission via GigE ExposureActive Image sequence recording is enabled for current frame start at first image end at last...

Page 8: ...RV Customer Device Sensor All inputs can be used as logical inputs but not for time critical tasks Electrical Parameters of Digital Outputs Multi Function Connection The digital outputs require an ext...

Page 9: ...Communication with sensor possible Constant red Error during initialization No communication with sensor possible LED Power Meaning Off No operating voltage or operating voltage too low Constant gree...

Page 10: ...itializa tion After completion it is constantly illuminated green For more information see the LED Displays section see Chap 7 i The surfaceCONTROL 3D 35xx sensor requires a warm up time of typically...

Page 11: ...y surfaces reflections from the test object can be reduced by inclining the sensor by up to 30 with respect to the surface of the test object Alignment with Crosshair You will achieve the best results...

Page 12: ...aused by improper handling the use of force or by repairs or modifications by third parties is not covered by the liability for material defects Repairs are carried out exclu sively by MICRO EPSILON F...

Reviews: