Page 6
scanCONTROL 2910/2960BL
Ethernet Connection, Standard Connection to PC
RJ45 connector
8-pin. screw connector (sensor side)
Pin no. Color of stranded hook-
up wire SCR3000A-x
Pin no. 10BaseT,
100BaseTX
1000BaseT
1
White (orange)
5
Tx+
D1+
2
Orange
6
Tx-
D1-
3
White (green)
8
Rx+
D2+
4
Blue
1
D3+
5
White (blue)
2
D3-
6
Green
7
Rx-
D2-
7
White (brown)
3
D4+
8
Brown
4
D4-
1
View on pin side
of male cable
connector
2
3
4
5
6
7
8
1
View on solder side (ca-
ble) of screw connector
(A-coded)
- The sensor supports an automatic, sensor-adapted IP address in the link-local-net
(169.254.x.x). No collision check is performed. This is also the standard setting.
- The sensor supports DHCP. This setting is activated by default and has priority over
the retrieval in the link-local net.
- The sensor scanCONTROL 2610/2960BL supports Power over Ethernet.
If the sensor is connected to a POE-capable network adapter/
switch and you also use the power supply of the multifunction
port, these two power supplies must be galvanically isolated.
> Damage to the sensor and /or Ethernet card!
- A fixed IP address can be assigned.
Use the
sensorTOOL
program to make specify the sensor settings described
above.