Page 16
Functional Principle, Technical Data
optoNCDT 1320
3.3
Technical Data
Model
ILD1320-10
ILD1320-25
ILD1320-50
ILD1320-100
Measuring range
10 mm
25 mm
50 mm
100 mm
Start of measuring range
20 mm
25 mm
35 mm
50 mm
Midrange
25 mm
37.5 mm
60 mm
100 mm
End of measuring range
30 mm
50 mm
85 mm
150 mm
Linearity
1
12 µm
30 µm
60 µm
120 µm
≤ 0.12 % FSO
Reproducibility
2
1 µm
2.5 µm
5 µm
10 µm
Measuring rate
0.25 kHz / 0.5 kHz / 1 kHz / 2 kHz
Light source
semiconductor laser <1 mW, 670 nm (red)
Permissible ambient light
10,000 lx
Spot diameter
± 10 %
SMR
90 x 120 µm
100 x 140 µm
90 x 120 µm
750 x 1100 µm
MMR
45 x 40 µm
120 x 130 µm
230 x 240 µm
EMR
140 x 160 µm
390 x 500 µm
630 x 820 µm
smallest ø
45 x 50 µm at 24 mm
55 x 50 µm at 31 mm
70 x 65 µm at 42 mm
---
Laser safety class
class 2 IEC 60825-1: 2015-07
Temperature stability
± 0.03 % FSO/°C
Operation temperature
0 ... +50 °C (non-condensing)
Storage temperature
-20 ... +70 °C (non-condensing)
Output
analog
4 ... 20 mA; 12 bit
free scalable within the nominal range
digital
RS422 / 16 bit resp. 18 bit
Vibration
20 g / 20 ... 500 Hz (acc. to IEC 60068-2-6)
Shock
15 g / 6 ms / 3 axes (acc. to IEC 60068-2-29)