background image

Instruction Manual 

ELTROTEC Endolight FOT Halogen 150

Summary of Contents for ELTROTEC Endolight FOT Halogen 150

Page 1: ...Instruction Manual ELTROTEC Endolight FOT Halogen 150 ...

Page 2: ...e MICRO EPSILON Eltrotec GmbH Manfred Wörner Straße 101 73037 Göppingen Germany Tel 49 0 7161 98872 300 Fax 49 0 7161 98872 303 e mail eltrotec micro epsilon de www micro epsilon com Certified acc to DIN EN ISO 9001 2008 ...

Page 3: ...ion 8 2 2 Technical Data 8 3 Delivery 9 3 1 Unpacking 9 3 2 Storage 9 4 Mounting 10 4 1 Light Source 10 4 2 Control Elements 11 5 Operation 12 5 1 Getting Ready for Operation 12 5 2 Commissioning 12 5 3 Adjust the Input Voltage 110 230 V 14 5 4 Fuse Replacement 15 5 5 Changing the Lamp 16 6 Instructions for Operation 18 6 1 General 18 6 2 Cleaning 18 6 2 1 Housing and Power Supply 18 6 2 2 Quartz ...

Page 4: ...ELTROTEC Endolight FOT Halogen 150 7 Warranty 19 8 Service Repair 19 9 Decommissioning Disposal 19 Appendix A 1 Optional Accessories 20 A 2 Spare Parts 23 A 3 Factory Setting 24 ...

Page 5: ...nu in the software 1 2 Warnings Connect the power supply in accordance with the safety regulations for electrical equipment Danger of injury Damage to or destruction of the light source Do not look directly into the light source Danger of injury damage to the eyes or skin Let the light source cool off for a few minutes before changing the lamp Risk of burns by the still hot lamp Pay attention to t...

Page 6: ...11 65 EU RoHS category 11 Products which carry the CE mark satisfy the requirements of the quoted EU directives and the European standards EN listed therein The EC declaration of conformity is kept available according to EC regulation article 10 by the authorities responsible at MICRO EPSILON Eltrotec GmbH Manfred Wörner Straße 101 73037 Göppingen Germany The ELTROTEC Endolight FOT Halogen 150 lig...

Page 7: ...in the limits specified in the technical data see Chap 2 2 Use the ELTROTEC Endolight FOT Halogen 150 light source in such a way that in case of malfunctions or failure personnel or machinery are not endangered Take additional precautions for safety and damage prevention for safety related applications 1 5 Proper Environment Operating temperature 10 C to 40 C 1 14 F to 104 F 1 Storage temperature ...

Page 8: ...d Different adapters and glass fiber applications permit various uses 2 2 Technical Data Model ELTROTEC Endolight FOT Halogen 150 Power 150 W Fiber diameter 13 mm Operating life type without economy mode 100 h with economy mode 210 h Weight 5 9 kg Power supply 110 V 60 Hz 230 V 50 Hz Light source 15 V 150 W Osram HLX type 64634 Color temperature 3400 K Lamp circuit Step I 100 intensity Step II 92 ...

Page 9: ...ll find the suitable fiber optics and fiber optic lighting units under Optional Accessories see Chap A 1 Check the delivery for completeness and shipping damage immediately after unpacking In case of damage or missing parts please contact the manufacturer or supplier immediately 3 2 Storage Storage temperature 25 C to 60 C 13 F to 140 F 1 Humidity 15 to 95 Ambient pressure Atmospheric pressure ...

Page 10: ...T Halogen 150 4 Mounting 4 1 Light Source 40 1 57 140 5 51 180 7 09 240 9 45 Fig 1 Dimensions ELTROTEC Endolight FOT Halo gen 150 front view Fig 2 Dimensions ELTROTEC Endolight FOT Halogen 150 side view Dimensions in mm inches not to scale ...

Page 11: ...oltage selector with fuse holder 2 Screw for the front door mounting Open for changing the lamp 9 Power input 3 Iris diaphragm control lever Fig 3 Control elements front side and rear side 4 Anti rotating device keyway 5 Fiber optic connection 6 Economy switch 2 position 7 ON OFF switch with control lamp ...

Page 12: ... is on 250 see Chap 5 3 are not occupied and cannot be used If the voltage selector has this setting the light source can therefore not be used Connect the supplied power supply cable to the power input 9 see Chap 4 2 and the power supply Connect the fiber optic cable to the fiber optic connection 5 see Chap 4 2 Some fiber optic cables e g multi armed gooseneck fiber optic cables and adapters are ...

Page 13: ...by heat The lamp power can be adjusted by economy switch 6 see Chap 4 2 If there is sufficient light the switch should be on level II intensity 92 Thus a longer lamp lifetime can be achieved The light intensity can be adjusted steplessly with the iris diaphragm control lever 3 see Chap 4 2 The light adjustment is made by a mechanical iris diaphragm without interference of the color temperature CAU...

Page 14: ...ositioning arrow points to 230 2 see Fig 4 To adjust the input voltage to 110 VAC raise the voltage selector element at the designated cut see Fig 4 see Fig 5 using a screw driver and pull it out 2 3 1 4 1 Voltage selector element 2 Positioning arrow 3 Cut to raise the voltage selector element 4 Power supply cable connection Fig 4 Detail rear side of light source Fig 5 Raise the voltage selector e...

Page 15: ... 20 mm 2 AT is in the voltage selector element 8 see Chap 4 2 Raise the voltage selector element see Fig 4 at the designated cut using a screwdriver 1 and pull it out 2 1 2 3 Fig 6 Fuse replacement Remove the defective fuse 3 and insert a new fuse 2 AT Please use only the fuses recommended in the appendix under optional accessories 2 AT see Chap A 1 Insert the voltage selector element again and pr...

Page 16: ...e of the lamp by finger prints and dust Switch off the ON OFF switch see Fig 3 and disconnect the power supply cable from the wall socket Remove the screw see Fig 3 on the front side of the light source 1 whereupon the right front door with the lamp unit can be folded down 2 Loosen the lamp out of the holder carefully 3 lift the spring clip slightly 4 and pull the lamp from the lamp socket 5 1 Rem...

Page 17: ...ion them into the holder i Make sure that the lamp coding is placed again in the designated cut Other settings are not required as the holding system provides an optimum adjustment with a footprint up to 13 mm maximum applicable fiber diameter Close the front door and mount it again with the screw see Fig 3 Plug in the power supply cable ...

Page 18: ...e ELTROTEC Endolight FOT Halogen 150 light source and disconnect the power supply cable from the wall socket and from the rear side of the device Wipe the exterior surfaces using a damp cloth with mild soapy water Wipe the power supply cable using a damp cloth with mild soapy water 6 2 2 Quartz Glass of Light Source Remove any fingerprints using a cotton swab or isopropyl alcohol rubbing alcohol N...

Page 19: ...nsequential damages MICRO EPSILON Eltrotec always strives to supply the customers with the finest and most advanced equipment Development and refinement is therefore performed continuously and the right to design changes without prior notice is accordingly reserved For translations in other languages the data and statements in the Ger man language operation manual are to be taken as authoritative ...

Page 20: ... packing density fiber bundle diameter 4 mm Length 1800 mm Metal protective conduit with PVC coating One side FOT light source connector One side Lemo1 connector cladding diameter 7 6 mm 20710831 Liquid fiber optic cable EFL 1 4 1800 MEP with Lemo 1 adapter Endoscope liquid fiber optic cable fiber bundle diameter 4 mm Length 1800 mm Cladding diameter Metal protective conduit with PVC coating One s...

Page 21: ... coating outer diameter 8 mm fiber bundle diameter 3 mm one side FOT light source connector 20710425 Faser optic lighting units Gooseneck attach ment Gooseneck attachment from semi rigid metal tube chrome plated Fiber bundle diameter 3 mm Attach able to cable type UL 20710430 Rigid probe Straight model UST A Attachable to UL fiber optic cables length 150 mm outer diameter 3 mm bundle diameter 2 mm...

Page 22: ...tion Article number Mirror deflection US1 mirror on fixture ø 21 mm 21060432 US2 mirror on fixture ø 25 mm 21060433 USP mirror fixture 21060431 Focussing lens Focussing lens UFL 21060438 attachable to UL fiber optic 21060438 More fiber optics or faser optic lighting units are available on request ...

Page 23: ...ight FOT 150 aperture ring 21310388 Endolight FOT 150 mounting ring for heat sink 21310389 Endolight FOT 150 power supply cable 21310402 Endolight FOT 150 fan CN 48 F2 21310401 Endolight FOT 150 transformer no 30950 21310400 Endolight FOT 150 Mounting connector with voltage selector 42 R 34 21310399 Endolight FOT 150 fuse no 543 21310398 Endolight FOT 150 power switch 21310397 Endolight FOT 150 la...

Page 24: ... protection filter with spring and bolt 21310393 Endolight FOT 150 aperture holder with mounting ring iris diaphragm 21310392 Endolight FOT 150 iris diaphragm 21310391 Endolight FOT 150 aperture holder for iris diaphragm 21310390 Power supply cable 1 5 m 21310402 A 3 Factory Setting Voltage input 230 VAC operating voltage ...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...CRO EPSILON Eltrotec GmbH Manfred Wörner Straße 101 73037 Göppingen Germany Tel 49 0 7161 98872 300 Fax 49 0 7161 98872 303 eltrotec micro epsilon de www micro epsilon com X9751285 A021059SWE X9751285 A02 ...

Reviews: