Page 29
Operation and Settings
English
colorCONTROL MFA-1
Manual Setup
6.5
To increase or reduce sensitivity levels in increments for optimum settings:
Press the button once or several times to increase sensitivity.
Press the button once or several times to reduce sensitivity.
Setup Help
6.6
This feature helps to find the correct working distance.
Press the button for 4 seconds until the symbol starts blinking.
The symbol can blink in 3 different frequencies, relative to the signal received.
The medium frequency range indicates the correct working distance.
Changing between Light and Dark Switching
6.7
Lo = Light switching
Do = Dark switching
Press the button for 4 seconds to switch between output signals.
i
Changing the output signal does not affect the switching state display.
Locking and Unlocking Buttons
6.8
Press the and buttons for 4 seconds to lock the buttons.
Repeat to unlock the buttons.