background image

CSE025/M5-CAm1,0/RS

Operating Instructions

capa

NCDT

 CST6110

Summary of Contents for capaNCDT CST6110

Page 1: ...CSE025 M5 CAm1 0 RS Operating Instructions capaNCDT CST6110...

Page 2: ...LON MESSTECHNIK GmbH Co KG K nigbacher Strasse 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 e mail info micro epsilon com www micro epsilon com Capacitive rotation speed measuri...

Page 3: ...npacking Included in Delivery 10 3 2 Storage 10 4 Mounting 11 4 1 Sensor Sensor Cable 11 4 2 Controller 12 4 3 Power Supply and Signal Cable SCAC3 6 IP68 13 4 4 Electrical Connections 13 4 4 1 Power S...

Page 4: ...capaNCDT CST6110 6 Troubleshooting 27 7 Liability for Material Defects 28 8 Service Repair 28 9 Decommissioning Disposal 28 Appendix...

Page 5: ...t avoided Indicates a user action i Indicates a tip for users Measurement Indicates hardware or a software button menu 1 2 Warnings Connect the power supply and the display output device according to...

Page 6: ...counting tasks The system must only be operated within the limits specified in the technical data see Chap 2 4 The system must be used in such a way that no persons are endangered or machines and othe...

Page 7: ...or This change in capacitance is detected and analyzed by the controller The rotational speed of measuring objects made of non conductive materials is also measured This requires a shorter distance be...

Page 8: ...range Storage 40 85 C 40 185 F Operation 40 85 C briefly up to 125 C Shock DIN EN 60068 2 27 20 g 5 ms in 3 axes 1000 shocks each Vibration DIN EN 60068 2 6 10 g 10 2000 Hz in 3 axes 10 cycles Protect...

Page 9: ...c 25 mm Mounting Screw connection via M5 thread Temperature range Storage 50 125 C 58 257 F Operation 50 125 C Humidity 0 95 r H non condensing Shock DIN EN 60068 2 27 50 g 5 ms in 3 axes 1000 shocks...

Page 10: ...the measuring system from the packaging and ensure that the goods are forwarded in such a way that no damage can occur Check the delivery for completeness and shipping damage immediately after unpack...

Page 11: ...Never bend the sensor cable more tightly than the permitted bending radius 10 x diameter for dynamic use 5 x diameter for static use i The calibrated sensor cables must not be short ened because this...

Page 12: ...T CST6110 4 2 Controller The controller can be fastened by using two M4 screws 43 1 69 12 47 52 2 05 42 1 65 24 94 18 71 53 2 09 15 3 60 24 94 6 24 30 1 18 Mounting holes for M4 screws Fig 3 Dimension...

Page 13: ...r pin side 6 pole cable connector Fig 4 Supply voltage connection 24 V 1 White 24 V supply 11 32 VDC reverse polarity protection 0 V 2 Gray Supply ground Analog out 3 Pink Signal output 0 5 V AGND 4 G...

Page 14: ...reversal i Power supply only for measuring devices not to be used for drives or similar sources of impulse interference at the same time MICRO EPSILON recommends the PS2020 power supply unit see Optio...

Page 15: ...he system detects ridges and grooves The sensor front may not touch the measuring object ridge Damage to or destruction of the sensor i The vibrations of a rotating mechanical shaft cause slightly lar...

Page 16: ...g claws on the plug connector snap into the device component and create a reliable connection between the two compo nents It cannot be separated by pulling on the plug connector s cable By contrast th...

Page 17: ...identified Rotational speed mea surement Green Measurement inside the measuring range Orange Measurement outside the measuring range MODE rota ry switch Description Measuring range Number of blades X...

Page 18: ...not possible The controller evaluates the pulses provided by the sensor For the Rotational speed measurement modes MODES 7 8 9 and TTL pulse per rotation MODE 3 the controller must know the number of...

Page 19: ...sition should always be fastened by the locknut except while it is being screwed onto the thread Observe how the color of the Status LED changes Status LED turquoise Too few pulses to check the signal...

Page 20: ...sor and ridge ap prox 5 mm Carefully continue to screw in the sensor i The connector on the sensor cable can be turned in the socket without needing to be pulled off You can continue to screw in the s...

Page 21: ...GNAL 2V Div TTL Fig 17 Screenshot of oscilloscope short distance low sensitivity Signals on oscilloscope after distance between sensor and measured object has been reduced without changing sensitivity...

Page 22: ...tance between the sensor and the measuring object min max Sensitivity potentiometer Status LED turquoise Measurement not possible RAW SIGNAL 2V Div TTL Fig 18 Screenshot of oscilloscope long distance...

Page 23: ...RAW signal is correct ly transformed into digital pulses without faults or pulse drops Status LED green Measurement possible RAW SIGNAL 2V Div TTL Fig 21 Screenshot of oscilloscope short distance low...

Page 24: ...nal transformation Measuring object does not turn turns very slowly see Fig 10 Increase rotational speed Sensor identifies too few signal peaks Continue to carefully screw in the sensor or increase th...

Page 25: ...tch for the output test Pin 3 analog output 1 V 1 5 V 2 V 5 V for measuring object dividers from 1 10 0 V for measuring object dividers from 11 16 Pin 5 TTL pulses t i approx 100 s t p varies dependin...

Page 26: ...r max 100 000 rpm Fig 25 Signal for max 200 000 rpm Fig 26 Signal for max 400 000 rpm The controller outputs an analog signal for the operating modes 0 Signal test 4 5 6 Frequency measurement 1 Output...

Page 27: ...bed see Chap 5 4 Change the sensitivity on the controller Change the distance between sensor and measured object Provide the controller with its own power supply If you use measuring devices e g an os...

Page 28: ...MICRO EPSILON shall not be liable for any consequential special indirect or incidental damage In the interest of further development Micro Epsilon reserves the right to make design changes without no...

Page 29: ...Page 29 Appendix capaNCDT CST6110 Appendix Optional Accessories PS2020 Power supply unit for DIN rail mounting Input 230 VAC Output 24 VDC 2 5 A...

Page 30: ...KG K nigbacher Str 15 94496 Ortenburg Germany Phone 49 8542 168 0 Fax 49 8542 168 90 info micro epsilon de www micro epsilon de Your local contact www micro epsilon com contact worldwide X9751420 A01...

Reviews: