Page 6
Safety
capaNCDT CST6110
1.3
Notes on CE Marking
The following apply to the capaNCDT CST6110:
- EU Directive 2014/30/EU
- EU Directive 2011/65/EU
Products which carry the CE mark satisfy the requirements of the EU directives cited and the relevant applicable harmonized Europe-
an standards (EN). The measuring system is designed for use in industrial environments.
The EU Declaration of Conformity and the technical documentation are available to the responsible authorities according to the EU
Directives
1.4
Intended Use
- The system is designed for use in industrial and laboratory applications.
- It is used for industrial counting tasks.
- The system must only be operated within the limits specified in the technical data, see Chap.
- The system must be used in such a way that no persons are endangered or machines and other material goods are damaged in
the event of malfunction or total failure of the sensor.
- Take additional precautions for safety and damage prevention in case of safety-related applications.
1.5
Proper Environment
- Protection class (sensor):
IP67 (when connected)
- Protection class (controller):
IP67 (with closed lid and when connected)
- Temperature range (operation)
Sensor, sensor cable:
-50 ... +125 °C (-58 ... +257 °F)
Controller:
-40 ... +85 °C (-40 ... +185 °F), briefly up to 125 °C
- Temperature range (storage)
Sensor, sensor cable:
-50 ... +125 °C (-58 ... +257 °F)
Controller:
-40 ... +85 °C (-40 ... +185 °F)
- Humidity:
5–95% (non-condensing)
- Ambient pressure:
Atmospheric pressure
- Power supply
11 ... 32 VDC