Step 7: Connecting the BROWN wire 

 

Follow the wire that connects the C terminal on the run 
capacitor to the contactor. Disconnect the compressor 

“R” terminal wire located on the same side of the 

contactor. This wire is often a heavy gauge wire 
connected to the screw part of the contactor. It may 
also be on a quick connect as shown in figure 5.  

 

 

Connect the disconnected wire to the BROWN wire 
from EasyStart. Connect only these two wires together 
and not to anything else.  

 

 

 

 

 

Step 8: Connecting the WHITE wire 

Connect the EasyStart WHITE wire to the contactor where the wire was removed from in the last step. 
This is typically under the screw terminal on the contactor.  

Note:

 Compressors with an RLA over 18 amps should not use the spade connection like shown 

in figure 5 but should connect using a ring, fork or direct wire connection under the screw. Be sure to 
match whatever method is used for the original installation. 

 

 

 

Figure 5 

Summary of Contents for EasyStart Home

Page 1: ...terminal run capacitors 4 Two terminal run capacitors 4 Step 4 Removing start devices 5 Step 5 Check for compressor monitoring systems 5 Step 6 Connecting the ORANGE wire 5 Step 7 Connecting the BROWN wire 6 Step 8 Connecting the WHITE wire 6 Step 9 Connecting the BLACK wire 7 Step 10 Learning 7 Appendix 1 Compressor monitoring system changes 8 Models without Bluetooth 8 Models with Bluetooth 8 Ap...

Page 2: ...g with AC line voltages please seek installation by a qualified HVAC or electrical professional Turn off all power to the air conditioning system before proceeding Read all instructions before starting installation Capacitors can store a charge and should be discharged by touching both terminals simultaneously with an insulated screw driver Three terminal caps should use the C terminal to short ea...

Page 3: ...dditional components and may have a circuit board as well Power comes in from the bottom of the contactor usually from a breaker or fuse panel on the dwelling This must be disconnected Turn the breaker off before connecting EasyStart Step 2 Mounting the unit EasyStart can be mounted on any flat surface in either a horizontal or vertical position It can also be mounted with the clear cover pointing...

Page 4: ...re to make connections Two terminal run capacitors Wire to contactor and capacitor Two terminal group caps are harder to identify the terminals because they are not labeled Look for a wire that connects the contactor to the capacitor like the red one shown in figure 3 This wire is connected to the C terminal and will be left in place The other unmarked terminal is the HERM terminal For the remaind...

Page 5: ...h is a small disk Remove this start assist wire from the herm terminal at both ends while leaving all the other HERM wires alone If you have a PTC or hard start you can just remove the entire device Step 5 Check for compressor monitoring systems Some systems have monitoring circuit that verifies the compressor is running and provides feedback like a lights or fault indication when the compressor f...

Page 6: ...nect the disconnected wire to the BROWN wire from EasyStart Connect only these two wires together and not to anything else Step 8 Connecting the WHITE wire Connect the EasyStart WHITE wire to the contactor where the wire was removed from in the last step This is typically under the screw terminal on the contactor Note Compressors with an RLA over 18 amps should not use the spade connection like sh...

Page 7: ...rent in your installation Connect the BLACK EasyStart wire to the side of the contactor where the EasyStart WHITE wire is NOT connected using an available connection point Connect here Step 10 Learning Start the air conditioner on AC mains power The fan will come on followed shortly after by the compressor EasyStart is now installed The compressor can be cycled normally to complete the learning pr...

Page 8: ...tion Turn off the breaker to the air conditioner Connect the black and white EasyStart wires to the line input side of the contactor indicated by the yellow arrows in figure 8 Tape or wire nut the EasyStart brown and orange wire ends so they cannot make electrical contact with anything Turn on the breaker to the air conditioner Open the smart device application on an Android or Apple device To sta...

Page 9: ...rmal rain events The box should not be pressure washed since it is not rated for high power water jet cleaning It can be washed with a mild soap and water solution Appendix 3 Additional Resources For additional information on EasyStart troubleshooting or assistance please visit our website at www Microair net ...

Reviews: