![Michco sc8000 Service Manual Download Page 45](http://html1.mh-extra.com/html/michco/sc8000/sc8000_service-manual_1784517045.webp)
Control System
44
Service Manual – SC8000
CONFIGURATION DISPLAY
Fault Codes
Detergent System
Press and hold the Emergency Flashers switch, then turn the key switch
on. Configuration display only – no changes to configuration allowed.
Stored fault codes are displayed in a list. Display
format: XX (two-digit error code) and brief description.
View Fault Codes
Clear Fault Codes
Are You Sure?
Press the Scrub On switch to clear the fault
codes. The display will show “No Stored Codes”.
Engine Type
Undefined, Propane, Gasoline, Diesel
Undefined / Propane / Gasoline / Diesel
Installed?
Display Format
Installed / Not Installed
Ratio / Percentage
EcoFlex System
Installed / Not Installed
Side Scrub System
Installed / Not Installed
Side Sweep System
Installed / Not Installed
Extended Scrub System
Installed / Not Installed
Back-up Alarm
Installed / Not Installed
Will be displayed if there are no
stored fault codes.
No Stored Codes