Recovery System 137
Service Manual – SC8000
Specifications
Component
Specifications
Fan Assembly Motor
Shaft Rotation – Clockwise (as viewed from shaft end)
Pressure Ratings:
• 3000 PSI – Continuous
• 4000 PSI –Intermittent
Displacement – 0.129 CIR
Vacuum Water Lift (Sealed)
33.7 inches H
2
O @ 2200 RPM
Vacuum Fan Solenoid Valve
L1
Current – 1.5 Amps
Nominal Coil Resistance – 8 ohms
Special Tools
Vacuum water lift gauge, p/n 56205281