![Michco sc8000 Service Manual Download Page 172](http://html1.mh-extra.com/html/michco/sc8000/sc8000_service-manual_1784517172.webp)
Solution System 171
Service Manual – SC8000
DustGuard
™
System
The
Mist Pump M5
pumps solution to the two DustGuard
™
nozzles adjacent to the side brooms while sweeping
to reduce dust. The following conditions must be met for the
Mist Pump
to operate:
• The DustGuard
™
system must be installed and enabled.
• The
Driver Box
must receive a signal from the
Dashboard Panel
via the CAN Bus that the Operator has
enabled the side brooms.
• The
Driver Box
must receive a signal from the
Drive Pedal Sensor R1
that the drive pedal has been moved
from the neutral position.
Fuse, 100A
Relay, Power
Dashboard Panel
Driver Box
K1
Battery
12 VDC
F1
Circuit Breaker, 15A
CB6
K1
B1
3
B
Relay, Power
J2-1
Ignition_KeyPos
J1-12
S1
Switch, Ignition
J1-3 CAN +
J1-2 CAN -
J6-3 CAN +
J6-1 (B+)
J6-2 (B-)
J6-4 CAN -
Twisted Pair
Twisted Pair
1
87
30
2
1
2
J1-10
J1-31
J1-11
1
3
2
Drive Pedal Sensor, 5K Ohm
R1
J3-18
CB2
Circuit Breaker, 20A
M5
+
-
M
Pump, Mist (optional)
J1-21
Switch, Solution Empty (closes when the
solution tank is empty)
1
2
S3
Bat -
B- (ground)