Mi-T-M
CD-GASOLINE Operator's Manual
7
operating instructions
cleaning witH detergents:
. Refer to "Detergent Cleaning Precautions" pg. 6 before working with
detergents. Be certain to wear protective safety attire as stated on pg.
2.
2. Prepare detergent solution according to label directions. Never pump
acids, alkaline, abrasive fluids or solvents through the unit. Due to the
unknown and often corrosive characteristics of many detergents commonly
used in the pressure washer cleaning industry, it is recommended to use
only Mi-T-M detergents with this unit.
3. Connect the detergent hose to the unit as shown on the Feature Page
pertaining to your unit. (Page 8 or 0.)
4. Adjust the amount of detergent desired by locating the adjustment knob
at the end of the clear vinyl hose near the pump head. Turn the knob
completely counterclockwise to set at the maximum siphon rate.
5. Immerse the strainer into the detergent solution to allow detergent to
siphon.
6. Be certain the water supply is completely turned "ON".
7. With the trigger gun locked in the "OFF" position, securely quick-connect
the detergent spray nozzle (#6540° BLACK) into the end of the wand.
NOTE:
This injection system is designed to apply detergents under low
pressure only. It will not allow detergent solutions to be introduced
into the system unless the nozzle assembly is in the low pressure
detergent mode.
8. To apply solution; unlock the trigger gun and squeeze the trigger. In a
few moments a detergent/water mixture will exit the low pressure nozzle.
Start spraying the lower portion of the surface being cleaned and move
up, using long overlapping strokes. Applying from the bottom up helps
avoid streaking. Allow to soak briefly. DO NOT allow detergent solution
to dry on the surface. (Avoid working on hot surfaces or in direct sunlight
to minimize the chances of the detergent drying, which may result in
damaging painted surfaces.) Be certain to rinse a small section at a
time.
9. To rinse; lock the trigger gun in the "OFF" position, securely quick-
connect the 40° nozzle into the end of the wand. Unlock the trigger gun
and spray. It will take about 30 seconds to purge all detergent from the
line. For best rinsing results, start at the top and work down.
0. Siphon a gallon of water through the low pressure detergent injection
system after each use. This prevents the possibility of corrosion or
detergent residue causing mechanical problems during the next use.
sHutdown:
. Turn engine "OFF" as directed in the Engine Manual.
2. Turn the water supply "OFF".
3. Pointing the gun in a safe direction, trigger gun momentarily to relieve
any trapped pressure.
4. Once pressure is relieved, disconnect the nozzle assembly.
5. Disconnect and drain gun, wand and hoses.
6. Wipe unit clean and store with gun, wand and hoses in a safe, non-
freezing area.
QuicK connect detergent
Summary of Contents for CD Series
Page 23: ...Manual del Operador 23 NOTES ...