8
Mi-T-M
®
CD-GASOLINE Operator's Manual
storage & maintenance
specific maintenance
ENGINE: The engine instructions that accompany your unit detail specific
procedures for maintenance of the engine. Following the engine
manufacturer's recommendations will extend engine work life.
PUMP:
Change the pump oil after the first 25 hours of operation. After initial
change, every 3 months or 250 hour intervals are recommended.
If oil appears dirty or milky, changes may be required in greater
frequency. Fill only to the dot on the oil sight glass using Mi-T-M
pump oil #AW-4085-0016. DO NOT overfill.
QUICK COUPLERS: There is an o-ring seal inside the female quick-coupler
at the water outlet of your unit. This o-ring will deteriorate or, if
the unit is allowed to pump without the high pressure hose or
nozzle attached, it may be blown out occasionally. Simply insert a
replacement o-ring to correct the leak. (Additional o-rings can be
purchased from your dealer.)
NOZZLES: Water flow through the spray nozzle will erode the orifice, making
it larger, resulting in a pressure loss. Nozzles should be replaced
whenever pressure is less than 85% of the maximum. The frequency
of replacement will depend upon such variables as mineral content
in the water and number of hours the nozzle is used.