MHSC Windsor WR244 Owner'S Manual Download Page 14

14

Windsor High Efficiency Wood Stove

30005124

tOujOuRS fOuRNiR uNE SOuRcE d’aiR fRaiS 
daNS la picE O l’uNit ESt iNStallE. l’
cHEc pOuR faiRE Si pEut avOiR pOuR RSul-
tat dE la faMiNE d’aiR d’autRE caRbuRaNt 
bRlE dES appaREilS Et lE dvElOppEMENt 
pOSSiblE dE cONditiONS HaSaRdEuSES.

l’appaREil  dEviENt  tRS  cHaud  EN  utili-
SatiON.  dE  gRavES  bRluRES  pEuvENt  
tRE  cauSES    SON  cONtact.  il  faut  tRE 
paRticuliREMENt  pRudENt  EN  pRSENcE 
d’ENfaNtS.

Soufflerie facultative :

 Modle S31105

120 V, Frequ 60 Hz, 0.75 Amps 2900 RPM

daNgER :

 Risque de secousse lectrique, dbran-

chez avant de procder a l’entretien.

important :

 Pour une meilleure performance de cet 

appareil au “allumage bas” le ventilateur doit fonction-
ner a vitesse bas.

installation

1.  Retirez tous les composants placs  l’intrieur du 

pole.

2.  Choisissez l’emplacement pour le pole. Cet appar-

eil ne doit pas tre install en-de des distances de 
dgagement minimales  respecter par rapport aux 
matires combustibles ( la page 10). Le pole doit 
tre install sur une surface non combustible. (Fig. 
1)

8”

8”

8”

*16”
**18”

A

B

D

E

C

F

C

F

ST1005
CDW244
clearances
9/08

Figure 1
Dgagement entre le pole et les matriaux combustibles

Mur arrire

Mur latral

Mur latral

Mur arrire

dgagement entre le pole et les matriaux combustibles

Une espace de 457 mm (18 po) jusqu’au raccord de la chemine peut
tre xig par le corps consitute ayant jurisdiction.
 

depuis le pole   

depuis le manchon de raccord

  A. Mur latral 

457 mm (18 po)  D. Mur latral 

648 mm (25

Z\x

 po)

  B. Mur arrire 

381 mm (15 po)  E. Back Wall 

445 mm (17

Z\x

 po)

  C. Coin 

175 mm (7 po)  F. Corner 

381 mm (15 po)

     

 

G. Plafond 

1422 mm (56 po)

  * tats-Unis 406 mm (16 po) 

** Canada 457 mm (18 po)

Le pole doit tre install sur un plancher inflammable, quivalent  
9,5 mm) 3/8 po “millboard”. Protecteur pour le plancher faut tre une 
minimal R evaluer de .446. Informez vous auprs de l’inspecteur en 
btiment de votre localit pour determiner si un permis est requis.

3.  Si des matriaux non combustibles ont t installs 

sur les murs, obtenez du fabricant de ces matriaux 
ou du bureau local d’inspection des btiments les 
distances de dgagement minimales  respecter.

4.  Installez des briques rfractaires. (Fig. 2)
5.  Installez le tuyau  fume  L’INTRIEUR du collier 

de la chemine, sur le dessus du pole poru relier le 
pole et la chemine.

6.  N’UTILISEZ PAS de chenets dans votre pole.

34
#$7BRICKPLACE

2 Briques 
compltes

Dflecteur

Assurez vous de bien installer deux briques 
entieres dans le dflecteur tel que montre ci 
dessus (S16040)

ST1006

Figure 2
Installez des briques

tuyau  fume

1.  Prvoyez au moins 18 po de dgagement entre le 

tuyau  fume et les autres matraux combustibles. 
Vrifier avec les autorits ayants juridiction dans 
votre rgion.

2. Toutes les sections de tuyau doivent tre raccordes 

de sorte que la partie mle (extrmit dentele) soit 

oriente vers le pole.

3.  Fixez le tuyau  fume sur le collier de la che-

mine  l’aide de trois vis  mtal. Faites de mme  
chaque joint additionnel pour que toute votre instal-
lation soit bien rigide.

4.  Conservez le diamtre de chemine requis su toute 

la hauteur de l’installation.

5.  Si vous raccordez le pole sur une ancienne che-

mine de maonnerie, faites-la inspecter pour voir si 
elle est fissure; obtenez une valuation de son tat 
gnral; vous devrez peut-tre en faire modifier la 
dimension  l’aide d’un cheminsage en acier inoxyd-
able.

Si vous ne respectez pas les distances de dgage-
ment minimales requises et ne disposez pas sur 
une surface non combustible, votre installatio pour-
rait prsenter des problmes de scurit.

Summary of Contents for Windsor WR244

Page 1: ...ictions and installation inspection requirements in your area This stove is listed by OMNI Test Laboratories of Port land Oregon to meet UL1482 for the US and ULC 627 for Canada Do Not Discard This Ma...

Page 2: ...uncontrolled burn or a glowing red part or chimney connector indicates excessive draft Inad equate draft may cause back puffing into the room and plugging of the chimney and or cause the appliance to...

Page 3: ...N DO NOT open fire door to a point where it would be in contact with the combustible sidewall CAUTION Brick for ash drawer must be installed before operation of wood heater Optional Fan An optional he...

Page 4: ...nstructions Operation Do not use a grate or elevate fire Build wood fire direct ly on hearth When the stove is used for the first time the solvents in the paint will smoke off Wood This heater is desi...

Page 5: ...being careful not to overload Inlet Air Control Settings Desired Inlet Approx Burn Setting Air Setting BTU Output Low Closed Fully 10 600 Med Low 1 4 Open 12 118 Med High 3 4 Open 19 413 High Fully Op...

Page 6: ...ority for information on how to handle a chimney fire Have a clearly understood plan to handle a chimney fire WARNING Things to remember in case of chim ney fire 1 Close draft control 2 Call the fire...

Page 7: ...ys a large quantity of thick black smoke present in the firebox A large quantity of thick black smoke in the firebox is a good indication that the draft is poor 7 Is it normal for soot to cover the gl...

Page 8: ...n doubt contact a chimney expert and or chimney manufacturer for help Clean chimney rain caps and especially spark arrester regularly to prevent creosote build up which will signifi cantly reduce chim...

Page 9: ...1 S31117 3 1 8 Glass Gasket 4 S15001 4 5 8 Door Gasket 4 5 S15011 5 Spring Handle 1 90000069 6 Air Control Spring Handle 1 90000070 7 Glass Clip 6 S37034 8 Screw 6 S11086 9 Hinge Pin 2 S11005 10 Push...

Page 10: ...horized MHSC supplier or MHSC Customer Service Department 10 MHSC will not be responsible for Down drafts or spillage caused by environmental conditions such as near by trees buildings rooftops hills...

Page 11: ...11 Windsor High Efficiency Wood Stove 30005124 MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Page 12: ...le Mod le WR244 non catalytique Ce po le respecte les limites d mission pour les po les bois fix es par l agence Am ricaine de protection de l environnement Dans des conditions sp cifiques ce po le d...

Page 13: ...d air au del de son r glage normal 11 N INSTALLEZ PAS cet appareil dans une maison mobile ou dans une remorque Ces appareils ne sont pas con us pour tre utilis s dans les maisons mobiles Fonctionneme...

Page 14: ...it tre install sur un plancher inflammable quivalent 9 5 mm 3 8 po millboard Protecteur pour le plancher faut tre une minimal R evaluer de 446 Informez vous aupr s de l inspecteur en b timent de votre...

Page 15: ...po 406 mm aux tats Unis de chaque c t domportant une porte et de 203 mm 8 po des autres c t s Aux tats Unis le rev tement doit couvrir les tuyaux fum e horizontaux et d passer de 51 mm 2 po de chaque...

Page 16: ...ter la temp rature 500 degr s F 260 370 degr s C pendant au moins 45 minutes Il faut que la peinture vieillisse lentement vitez les feux vifs pendant le vieillisse ment de la peinture Pendant le m ris...

Page 17: ...r la vitre utilisez une vitroc ramique Robax de m me dimension et paisseur Remplacement d un joint Apr s un usage intensif le mat riau des joints de la porte et de la vitre peut devoir tre remplac s i...

Page 18: ...lle doit d abord rester dans son contenant jusqu ce qu elle soit compl tement refroidie Aucun autre rebut ne doit tre mis dans le contenant IMPORTANT Conseils qui valent la peine d tre r p t s 1 Quell...

Page 19: ...s que la temp rature de la chambre combustion et le tirage augmentant la sule br lers 8 Qu entend on par tirage Le tirage peut tre exprim comme tant la capacit de la chemin e vacuer les sous produits...

Page 20: ...ande d admission d air au complet lorsque je ferme le po le Lorsque vous fermez le po le ouvrez la commande d admission d air au complet Cela permet la temp rature de la chemin e de rester aussi lev e...

Page 21: ...6 S37034 8 Vis 6 S11086 9 Goupille de charni re 2 S11005 10 crou resorte 2 S11090 11 Brique 9 x 4M zn x 1Z v 12 S16040 12 Brique 7Z v x 4M zn x 1Z v 4 S16043 13 Brique coup e en angle 2 S16042 14 Jam...

Page 22: ...22 Windsor High Efficiency Wood Stove 30005124...

Page 23: ...es lesmontagnes ou une concep tion de chemin e inad quate de la ventilation inad quate des d volements excessifs ou de la pression d air n gative caus s par des syst mes m caniques tels que les foyers...

Page 24: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...