9
70D0004
TPB Series Log Set
FP1998
heat resist mantel
CLEARANCES and HEIGHT REQUIREMENTS
Hood
Heater in
Fireplace or
Firebox
8" or More of
Heat Resistant
Materials
FP1998
Figure 6 -
Measuring Heat Resistant Material
for Mantel
Heat Resistant
Material
Requirements for Safe Installation
Measurement
TPB18
TPB24 / TPB30
1” or more
Hood not required.
Hood not required. Observer profile
Observe profiles
(side elevations) shown in Figure 9.
shown in Figure 7
8” or less than 1” Install hood and
Install hood and observe profiles shown
observe profiles in
Figure 7; OR extend heat resistant
Figure 8; OR extend material to at least 1" and observe
heat resistant mat'l
profiles shown in Figure 9.
to at least 1" and
observe profiles.
Fig.7
Less than 8”
Extend heat resistant Extend heat resistant material to 8",
material to at least 8”, install hood and observe profiles.
Figure
install hood and
7; OR extend heat resistant material to
observe profiles in
at least 1" and observe profiles in
Figure 8; OR extend Figure 9.
heat resistant mat'l
to at least 1" and
observe profiles in
Figure 8.
TABLE B -
Heat Resistant Material Heights and Mantel Location
FP2865
minimum mantel clearance no hood
2
56O
”
6 ”
8 ”
10 ”
8 ”
14”
20
56O
”
24
6
”
28 ”
Heat
Resistant
Material
Heater in
Fireplace or
Firebox
FP865
Figure 7 -
Minimum Mantel Clearance with No Hood
- TPB18
Example:
A mantel may
project from the wall a
maximum
of
Z\x
" at a
minimum
of 14" above
the opening, and a maxi-
mum of 6" at a
minimum
of 0
Z\x
" above the open-
ing.
F P 19 9 9
m i n . m a n t e l c l e a r a n c e
2
56O
”
6 ”
8 ”
10 ”
12”
8 ”
14
56O
”
18
6
”
22
56O
”
26 ”
Figure 8 -
Minimum Mantel Clearance with Hood - All Models
Heat
Resistant
Material
Hood
Heater in
Fireplace or
Firebox
FP1999
Example:
A mantel may
project from the wall a
maxi-
mum
of
Z\x
" at a
minimum
of 8" above the opening,
and a maximum of 6" at a
minimum
of 14
Z\x
" above
the opening.