5
70D0004
TPB Series Log Set
PRODUCT FEATURES and SPECIFICATIONS
GAS PRESSURES
*Natural **Propane (LP)
Inlet Minimum
5.0” w.c.
11.0” w.c.
Inlet Maximum
10.5” w.c.
13.0” w.c.
Pilot Regulator
3.5" w.c.
n/a
Regulator Pressure
3.5” w.c.
10.0” w.c.
*NOTE:
An external regulator is required to reduce supply
pressure to a maximum of 10
Z\x
" W.C. on natural gas sys-
tems operating at higher pressure.
**NOTE:
An external regulator is required to reduce sup-
ply pressure to a maximum of 13” w.c.
GAS SPECIFICATIONS
Max.Input Min. Input
Model
Fuel
Control
BTU/h
BTU/h
TPB18NV
Nat.
Millivolt
19,000
8,000
TPB18PV
LP
Millivolt
3,000
8,000
TPB4NV
Nat.
Millivolt
6,000
38,000
TPB4PV
LP
Millivolt
6,000
34,000
TPB30NV
Nat.
Millivolt
6,000
38,000
TPB30PV
LP
Millivolt
6,000
34,000
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of
matches or batteries.
Millivolt control with pilot has four (4) positions:
OFF
- All gas to the gas logs is shut off at the valve.
IGN
- Valve position to light/maintain a standing pilot.
ON
- Valve position to light/maintain the gas burner.
LOW/HI
- Variable position to control flame height (heat
output)
PILOT/ODS
The gas log heater is fitted with a specially designed
safety pilot (ODS assembly) which senses the amount of
oxygen available in the room and shuts the gas log heater
off if the oxygen level begins to drop below a satisfactory
level. The pilot can only be relit when adequate fresh air
is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a Millivolt (thermopile)
generator to provide power for remote activation.
MAkE SURE YOU HAVE RECEIVED ALL
PARTS
Check your packing list to verify that all listed parts have
been received. You should have the following:
•
Unvented Gas Log Burner Assembly
•
Two () Plastic Bags Containing Crushed Volcanic
Rock
•
Installation/Operating Instructions
•
Two () Anchoring Screws
•
Ceramic Fiber Logs / Refractory Logs
•
Rock wool
•
Grate Assembly
•
On/Off Log Switch Assembly
The following options may be used with the millivolt con-
trolled heater. These options are not packaged with the
log set.
•
Hand Held Remote w/Receiver
•
Wall Thermostat w/ 15' Wire
•
Wall Switch w/ 15' Wire
•
Hand Held Thermostat Remote w/ Receiver
•
Cast Iron Grate and Andirons
•
Riser Kit
Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance.
Do not
attempt to install any part of the appliance unless you
have all parts in good condition.
WHAT YOU WILL NEED FOR INSTALLATION
You should have the following items available before
proceeding with installation:
•
External regulator (for propane/LPG and 1/ lb.
natural gas systems only)
•
Piping which complies with local codes
•
Sediment trap (recommended)
•
Screwdriver
•
Tee joint.
•
Pipe sealant approved for use with propane/LPG
(Resistant to sulfur compounds)
•
Drill with 5/3 masonry bit
•
Pipe wrench or appropriate size crescent
•
Manual shutoff valve
Gloves are recommended when handling
ceramic fiber logs to prevent skin irritation
from loose fibers. Logs are fragile — handle
with care.
W
ARNING