SSTB11 Woodburning Fireplace

FIREPLACE INSTALLATION

Location Selection

Unpack  and  check  the  fireplace  and  chimney  for  dam-
age.  If any items have been damaged, report this to your  
dealer.    Before  beginning  the  installation,  be  sure  you 
have the proper parts in sufficient quantity.  Refer to re-
placement parts page for proper identification of parts.Do 
not substitute parts.  Use only parts listed for use with the 
Model SSTB11 fireplace.

Fireplace Installation

1.  Refer to Figure 1 for an example of a typical installa-

tion of the fireplace components.

2.  Be  sure  the  location  of  the  fireplace  will  provide  the 

required clearances indicated by 

Figures 2, 3 & 5

 and 

the minimum chimney air space clearance to combus-
tibles of 2”.

3.  Set  the  fireplace  in  the  desired  location  and  be  sure 

it  is  securely  supported  and  leveled.  Check  the  face 
of the fireplace with a carpenter’s level and if it is not 
plumb; correct it by placing shims under the edges of 
the fireplace.

4.  Block in the fireplace to prevent any shifting of the fire-

box. Secure the fireplace with nails or screws through 
the flanges located on each side of the fireplace. Do 
not enclose the fireplace until the combustion air duct 
and chimney pipes are installed.

NOTE:

  Some local codes may require electrically ground-

ing the fireplace and chimney.

Chimney Installation

In  order  to  assure  safe  and  satisfactory  performance  of 
the  fireplace,  it  is  very  important  to  properly  install  the 
chimney. This is an important part of the installation and 
the sections of this manual pertaining to chimney installa-
tion should be reviewed very thoroughly.
For your safety, some of the important things to remem-
ber in regard to chimneys are listed below:
1.  Use  only  parts  and  accessories  labeled  for  use  with 

this fireplace.

2.  Use only undamaged parts and accessories.
3.  Enclose the chimney where it passes through the liv-

ing spaces to prevent contact with and possible dam-
age to the chimney.

4.  Install firestop spacers at each ceiling level.
5.  Install the proper chimney cap or chimney housing on 

the  chimney  to  prevent  the  entry  of  rain  and  debris 
into the chimney and to assure the proper venting of 
smoke.

6.  Do not use more than four (4) elbows in the chimney.

NOTE:

 Flue outlet should be 24” above all portions of  the 

building within 10’ as shown in the illustration. The chim-
ney must not extend more than 90” above the roof without 
additional support.

AC617

Figure 11

2' Min.

2' Min.

3'

Min.

10'

3'

Min.

10'

AC617

RLTSKC8

2/11/98

NOTE:

  To select the proper chimney height, refer to 

Fig-

ure 1

. The flue outlet must be a minimum of 3’ above the 

highest point where the chimney penetrates the roof and 
a minimum of 2’ above all portions of the building within 
10’. If the chimney is to include elbows to offset the chim-
ney, refer to the Chimney Offset and Cap Installation sec-
tion of this manual. There must be at least 2” air space 
between all sections of the chimney and combustible ma-
terials between floors.

CHIMNEY INSTALLATION

1.  Lay  out,  cut  and  frame  openings  through  all  ceilings 

and the roof at the point where the chimney will pass 
through. Unless the chimney is to be offset, the point 
where the center line of the chimney will pass through 
the ceiling and roof can be determined with a plumb 
line  as  shown  in 

Figure  12

.  The  fireplace  should  be 

located  in  the  planned  installation  position. After  the 
center line is established and a nail is driven to mark 
the point, the opening can be cut if you are satisfied 
with  the  chimney  location  relative  to  ceiling  and  roof 
joists and/or any other obstructions. The roof  opening 
center line should be marked by driving a nail through 
the  roof  from  underneath  that  will  penetrate  the  roof 
and can be located from the rooftop. If the chimney is 
to penetrate a pitched roof, the hole in the roof must 
be rectangular instead of square and should be sized 
according to Table 1.

FP 548b

SHR

5/11/99   djt

Angle of Chimney at Ceiling

Size of Chimney

Vertical

30˚

11" CF 2-Wall

FS2A

17

56O

" x 17

56O

"

(445 x 445 mm)

FS6A

17

(6 

" x 29

"

(454 x 753 mm)

CHIMNEY HOLE SIZE

Table 1

Summary of Contents for SSTB11

Page 1: ... Installation Operation and Maintenance Manual For Residential or Manufactured Home Installation 87D0174 2 10 Rev 4 530943 SSTB cover This fireplace is listed by OMNI Test Laboratories for use with 11CF Series Chimney System Components ...

Page 2: ...on you should check with local building officials to obtain required permits and assure compliance with local regulations and coded If you encounter problems with code requirements contact your dealer for assistance These Fireplace models are listed by OMNI Test Laborato ries Inc to U L 127 standard for factory built fireplaces The design of this fireplace and these instructions complied with appl...

Page 3: ...can cause 1 Damage to the fireplace from overheating 2 Hazardous temperatures to develop on combustible materials adjacent to the fireplace or chimney 3 The emission of smoke sparks or hazardous gases into the dwelling 4 Leakage of rain water into the dwelling Intended Product Usage The fireplace is designed to sit directly on a combustible floor The fireplace must be installed with zero clearance...

Page 4: ...e drawn out of the fireplace opening creating risks of both fire and smoke All fireplace chimneys are in direct contact with cold air on the exterior of the structure Consequently when the fireplace is not in use cold air can fall down the chimney of the fireplace to cool off the fireplace chase Therefore the fireplace chase must be insulated to minimize the risk of cold air infiltration to the ho...

Page 5: ...h incoming air is drawn into the home to equalize pressure Depressurization is a contributing factor to back drafting 75 of the time and is the sole cause of back drafting 40 of the time The greater the exhaust capacity and the tighter the building envelope the more a house will depressurize The combination of forces of exhausting air from the house can be so strong that it is possible for hot flu...

Page 6: ...F3 3 ft pipe 11CF4 4 ft pipe Maintain 2 Minimum Air Space Between Chimney and Combustibles Fireplace Model SSTB11 Flexible Duct Type FP 4 U Optional Combustion Air As sembly Optional Metal Safety Strip Floor Line Top Spacer Firestop Requires 17 x 17 framing WH36 Glass Doors standard Gas Line Optional Combustible materials should not be installed below top spacer Noncombustible materials such as br...

Page 7: ... 1056M 12 6M 1556M 256O 9556QE 9 16 Ref 4 1156QE 2356M 856QE 42 6 465 6QE 38 42 4356O Min Framing Dim 3 4 Ref 3 4 539043 SSTB dims FIREPLACE DIMENSIONS Figure 2 Front View Side View Gas Line Opening Outside Air 1 Side Only Glass Doors Re moved for Clarity Top View Air Space Required to Combustibles ...

Page 8: ...e locations When selecting a loca tion choose one that is away from frequently opened doors central heat outlets or returns or other places where air movements may disturb the airflow around the fireplace Air turbulence near the fireplace may cause smoke to spill out of the fireplace opening CAUTION Do not install fireplace over carpeting 0 FIREPLACE LOCATION 16 3 4 2 6M Min 60 3 4 8 Model H1652 H...

Page 9: ... the chimney to pass through If the chimney is to pass through living or storage spaces be sure there is adequate space to enclose the chimney to avoid personal contact with or damage to the chimney 13 Min FP1881 single story install 8 08 Figure 5 Single Story Installation with Attic Space Chimney Cap Storm Collar Flashing 17 Square Opening in Joist 2 Min Clearance to Combustibles 11CF Series Chim...

Page 10: ...th the fireplace and extended under the hearth extension or into a mortar joint of the hearth extension as shown by Figure 9 In the event a crack does eventually develop the metal safety strip will serve as a barrier to prevent sparks or embers from falling from the fireplace onto combustible flooring materials 0 FIREPLACE LOCATION 16 3 4 2 6M Min 60 3 4 8 Model H1652 Hearth Extension Model H1652 ...

Page 11: ...spacer One required at each ceiling or floor level FS6A 30 Firestop spacer for 30 chimney incline through ceiling or floor FP 4 U 4 flexible combustion air duct 8 foot lengths FP 6 U 6 flexible combustion air duct 8 foot lengths For manufactured home installation 403 4 inch duct connector for splicing FP 4 ducts Includes two clamps AK4 4 outside combustion air assembly AK6 6 outside combustion air...

Page 12: ... dam age to the chimney 4 Install firestop spacers at each ceiling level 5 Install the proper chimney cap or chimney housing on the chimney to prevent the entry of rain and debris into the chimney and to assure the proper venting of smoke 6 Do not use more than four 4 elbows in the chimney NOTE Flue outlet should be 24 above all portions of the building within 10 as shown in the illustration The c...

Page 13: ...d to the previous section If additional strength of the outer pipe joints is desired you may use two or three sheet metal screws placed through the area where the outer pipes overlap one another To install these screws drill a 1 8 inch diame ter hole through the chimney sections taking care not to penetrate the inner flue pipe WARNING Be very careful when drilling the holes into the outer pipe The...

Page 14: ...supported at 6 intervals with support such as metal support straps 6 When enclosing the elbows and inclined portions of the chimney enclosing materials must be installed ver tically to maintain the required 2 minimum air space clearance to the chimney at the extremities of the off set It is recommended that enclosing material not fol low the inclined portions of the chimney 0 ELBOW Figure 15 Inlet...

Page 15: ...ey is measured from the hearth to the chimney exit SSTB11 Max 86 0 Min 0 Elbows 18 0 2 Elbows 24 0 4 Elbows 30 0 B Do not use more than 4 elbows per chim ney Attach the straps of the return top elbow to a structural framing member The offset first elbow of any pair does not have straps FP269 C The chimney cannot be more than 30 from the vertical plane in any instal lation D The maximum length of t...

Page 16: ...185 Figure 19 C L C L 0 MULTI STORY OFFSET Continue chimney through roof and install round chimney cap or chimney housing Firestop Spacer 2 Minimum Air Space Clearance at Joist Vertical Chimney Enclosure Chimney Must Be Enclosed in Accessible Areas Firestop Spacer Diagonal Chimney Enclosure RISE Firestop Spacer 2 Air Space Clearance to Combustibles NOTE Four 4 elbows may be used when toatl install...

Page 17: ...c Leave some excess mastic at this area to be used in step eight NOTE Use pliers and wear gloves when performing step seven to mini mize the danger of cutting your hands on the edge of the storm collar 7 Place the storm collar around the chimney and put the collar together like a belt in belt loops Slide the end of collar under the two loops on the other end with the loops facing up Overlap the en...

Page 18: ...ould be at least 24 apart to help prevent smoke from a fireplace in use from being drawn down the chimney of a fireplace that is not in use Additional spacing between caps or staggering the height of the caps will further lessen the likelihood of this occurring 6 Place cap assembly into position by aligning the flue telescope into the last section of flue pipe and lower it down until the 3 cap leg...

Page 19: ... side of fire place with four 4 sheet metal screws provided NOTE The starting collar extends through the outer fireplace jacket and will seal against the firebox wall when secured as indicated FP1901 secure outside duct 8 08 Step 2 Secure outside duct to starting collar with duct clamp or screws Fireplace Outer Wrap AK4 Combustion Air Kit Shortest Toward Firebox AK4 Mounting Plate Firebox Insulati...

Page 20: ...combustion air inlet assembly should never be mounted in a garage or storage area where com bustible fumes such as gasoline might be drawn into the fireplace 4 Combustion air can be drawn from the crawl space under a house when an adequate supply of air is provided by open ventilation 5 Do not take combustion air from attic space or garage space Figure 26 Outside Air Control Lever Lift to Open Pul...

Page 21: ...three inches beyond the face of the wall to which the AK 4 inlet air vent will be attached The duct may be cut with a standard pocket knife use FP 4 U duct for maximum efficiency and safety Do not use a combustible duct Always use UL Listed Class 0 or 1 duct material 5 If the duct is the insulated type push the insulation back from one end of the duct approximately two inches 6 Slip the exposed en...

Page 22: ... appliance to the people who will be operating them and leave all instruction manuals with the operator of the fireplace NOTE When installing an ANSI Z21 11 2 ventless ap pliance the finishing material used for the mantel must be rated at 250 F or greater WARNING Do not operate an unvented gas log set in this fireplace with the chimney removed 2 An approved gas shut off valve must be located out s...

Page 23: ...ick 24 Max Fireplace Firebrick Hearth Brick Gas Line Access Tube Repack Insulation Around Gas Line Where it Passes Through Gas Line Access Tube for Proper Seal Maintain 1 2 Minimum Air Space Clearance to Combustibles for Gas Line Out to 4 From Side of the Fireplace Combustible Materials May Be Located at Zero Clearance to Gas Line Beyond 4 From Fireplace Side Side Brick Knockout Gas Line Plumbing ...

Page 24: ...nstalled below the top spacers of the fireplace or overlap the sides of the fireplace face Seal the face of the fireplace to the surrounding wall with non combus tible caulk or trim materials to prevent cold air leakage around the fireplace TRIM INSTALLATION 0 TRIM INSTALL 1156O Min 12 Min 156O Min Maintain 2 Min Clearance to Combustible Construction from Chimney Pipe Finish Wall Header Framing No...

Page 25: ...ture of softwood and hard wood then add some fruit or nut wood for nostalgic aro ma Since most woods will not burn well when freshly cut the wood you purchase should be reasonably dry The sizes you buy are dictated by the size of your fireplace Purchase logs that will fit when laid across your grate and ask that the larger heavier logs be split Kindling should be short easily split lengths of soft...

Page 26: ... These not only create air pollution but can induce extreme irritation for some individuals Use hemlock spruce juniper and other resinous woods with caution They contain moisture pockets which upon heating pop with considerable vigor Always use a fire screen And always bank a fire or at least push all unburned fuel to the rear of the grate before leaving a fire unattended Do not use this fireplace...

Page 27: ...rvices of a qualified and reputable chimney sweep or remove the accumula tion with brushes on wooden or fiberglass poles Do not use metal pipes chains wires etc to clean the chimney because such items can scratch the surface of the stain less steel flue which can shorten the life of the flue and provide a rough surface for soot particles to attach to Be sure to cover nearby furnishing and arrange ...

Page 28: ...al flashings that may be fabri cated locally 4 Don t use damaged parts or accessories with this fire place 5 Don t install the fireplace in an exposed or uninsu lated area 6 Don t install the fireplace over carpeting 7 Don t install the fireplace on a poorly constructed base or fail to fasten down or attach the fireplace to prevent it from shifting out of position 8 Don t create or allow a crack t...

Page 29: ...S IN FUEL OR FROM FUEL COMBUSTION WHICH CAN CAUSE DEATH OR SERIOUS ILLNESS AND WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER BIRTH DEFECTS OR OTHER REPRO DUCTIVE HARM ALSO OPERATION INSTALLATION AND SERVICING OF THIS PRODUCT COULD EXPOSE YOU TO AIRBORNE PARTICLES OF GLASS WOOL FIBERS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER THROUGH INHALATION MAINTENANCE SAFETY ...

Page 30: ...sy 2 036998 15 Air Deflector Ptd Assy 2 037005 16 Track Bottom Ptd Assy 2 036999 17 Left Door Assy 2 038851 18 Right Door Assy 2 038850 19 Glass Panel 8 038847 20 Retainer Glass Spring 32 038785 21 Air Divider Right 2 050156 22 Air Divider Left 2 050155 1 2 3 10 9 8 7 6 5 4 21 18 14 11 19 20 11 15 12 16 22 17 13 539043 SSTB parts 1 09 All repair part orders should be placed through your local deal...

Page 31: ...ur local building code contains restrictions on the use of this fireplace before you purchase it Blowers or fans which are warranted separately Heat loss due to the passage of heat or air through or around the fireplace Also under our five year coverage we do not pay the cost of removal and replacement of any portion of the structure in which the fireplace is situated made necessary by the repair ...

Page 32: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com ...

Reviews: