20301938
7
B-Vent Specialty Gas Fireplaces
CLEARANCES
CLEARANCE TO COMBUSTIBLES
Sides .......................................................... 1/2”
Back ........................................................... 1/2”
Top ................................................................ 0”
Front ............................................................ 37”
Bottom ........................................................... 0”
When the fireplace is installed directly on carpeting, vinyl
tile or other combustible materials (other than wood floor-
ing), it shall be installed on a metal or wood panel extend-
ing the full width and depth of the fireplace.
Provide adequate ventilation air.
Provide adequate accessibility clearance for servicing
and operating the fireplace.
Never obstruct the front opening of the fireplace.
8
56O
”
12”
9”
2
56M
”
FP2754
mantel clearance
Combustible Mantel
and Trim Allowed
Above Dotted Line
Measure from
Top of Opening
Front of Fireplace
FP2754
Figure 2 -
Mantel Clearances
MANTEL CLEARANCES
1"
2
56O
”
3"
4"
1
56O
”
2
56O
”
45°
FP2582
mantel side clearance
Combustible
Material Area
Wall
Side of Fireplace
Opening
Top View
FP2582