20301938
10
B-Vent Specialty Gas Fireplaces
VENTING INSTALLATION
7’
Min.
FP2207
straight up install
Storm Collar
Flashing
6” Type “B”
Gas Vent
Listed
Ceiling
Support
Minimum Clearance
as Specified by Vent
Manufacturer
“B” Vent Clearance
as Specified by Vent
Manufacturer
Wall
Gas Appliance
Floor
FP2207
Figure 6
&0
TRANSITIONPIPE
Attach 6” “B” Vent Pipe
to Transition using Four
(4) Sheet Metal Screws
Attach Transition to
Flue Collar using
Three (3) Sheet Metal
Screws
Units Flue Collar
FP2208
Figure 7
6‘ Min.
4’ Max
FP2009a
vent w elbows
Approved
Termination
Support
As Specified
by Vent Manu-
facturer
6” Type “B” Gas
Vent Chimney
Wall
Gas Appliance
Floor
Approved Thimble for
6” Type “B” Gas vent
Through Wall
FP2209
Figure 8
Peninsula and See-Thru
Models Only
NOTE:
This installation is
NOT
recommended for colder climates.
Check local codes for allowances.