19.3 control
panel
STATUS
Menu / Reset Button
Display
Minus "-"/Engineers
Button
Plus "+"/ Summer-Winter
Button
On/Off
Switch
Gauge For Heating
System Water Pressure (bar)
Test Button
MENU
RESET
TEST
1
1
0
4
3
2
0
+
-
The user interfaces on the boiler control panel include a double pole on/off switch, 4Nr membrane
button switches with click response, an LCD display screen with backlight and a mechanical dial type
pressure gauge to indicate heating system water pressure.
The membrane button switches (with the exception of the test button) are multi-function and have
varying operation depending upon the operational mode of the boiler.
When requiring to use the membrane button switches, light but firm finger pressure must be exerted
on the appropriate circular marking until a click response is felt/heard.
display
The back lit LCD display screen has two lines. The normal text displayed is:-
a) Upper Line – Indicates current status of boiler, e.g. “HW DEMAND”, and either “S” (summer) or “W”
(winter) / “D” (day) or “N” (night).
b) Lower Line – Indicates current flow temperature of boiler and real time.
menu/reset button
●
Gives access to the various menus
●
Scrolls through the current operational status
messages.
●
Confirms an entry during controls programming.
●
Resets the boiler following a “lockout”.
button
●
Advances (Scrolls forward) through menu.
●
Increases a value to be edited.
●
Sets controls to either summer (heating off ) or
winter (heating on) operation.
button
●
Reverses (scrolls backward) through menu.
●
Reduces a value to be edited
●
Sets appliance (for 10 minutes) into Engineers
mode for commissioning or checking purposes.
test button
●
Checks overheat safety circuit (during a burner
on mode; will cause burner to be shut down
and then re-ignited).
●
Checks boiler pump operation (during a burner
off mode; will cause pump to be operated at
100% speed for approx 2 seconds.
"+"
"
-
"