WC
RS
SV
IV
IV
IV
IV
IV
LSV
DOC
DOC
DOC
DOC
Condense
Waste
Expansion
Vessel
Filling Point
System Pump
HW
M/Valve
CH
M/Valve
Reg Valve
Heating Load
Indirect Cylinder/Calorifier
CS
Vertical Low Velocity
Mixing Header
Max Velocity
0.5 m/s
CWM
Strainer
Strainer
PS
OS
AAV
32
STRATA1
3 8 & 3 8 / 4 6 C O M B I
Low Velocity
Mixing Header
Max Velocity 0.5m/s
Circuit Pumps
That Can/Will Run
At The Same Time
Boiler/s
Flow Header
AAV
typical schematic arrangement where
system has multiple pumps that will
operate at the same time
WC =
Wiring Centre/Junction Box
RS =
Room Thermostat
CS =
Cylinder Thermostat
PS =
Low water pressure cut off switch.
OS =
Outside Air Sensor, install when
weather compensated heating flow
temperatures are required
system type 8
Typical Single Strata 1 boiler
installation serving heating and
domestic hotwater via a system
pump and 2Nr 2Port motorised
valves with conventional
controls i.e. programmer, room
stat & cylinder stat.
17.0 hydraulic system design (contd)